background image

 

Baler

Revision: 12/09

C o p y r i g h t   ©   2 0 0 3 - 2 0 0 9

C a m p b e l l   S c i e n t i f i c ,   I n c .

Summary of Contents for Baler

Page 1: ...Baler Revision 12 09 C o p y r i g h t 2 0 0 3 2 0 0 9 C a m p b e l l S c i e n t i f i c I n c...

Page 2: ......

Page 3: ...copy of the software is an upgrade from a previous version you must possess a valid license for the earlier version of software You may continue to use the earlier copy of software only if the upgrad...

Page 4: ...dia or documentation Campbell Scientific will correct errors without charge by providing new media addenda or substitute pages If Campbell Scientific is unable to replace defective media or documentat...

Page 5: ...2 Allowing Remote Connections 1 2 Baler Settings 2 3 File Naming and Directory Structure 4 4 Number of Files to Keep 4 5 File Format 4 6 Baler Operation 5 6 1 Baling Controls 5 6 2 Table Status and Me...

Page 6: ...This is a blank page...

Page 7: ...the CD ROM drive and select the setup executable 3 This activates the Baler Installation Utility Follow the prompts on the screen to complete the installation An item is added to your computer s Start...

Page 8: ...e recommend that this feature be disabled unless it is essential that the data be made available to a remote computer running the Baler or other remote LoggerNet client This option can be enabled disa...

Page 9: ...g has begun for a table baling will continue on the same schedule even if baling is paused and then restarted The only way to change the Initial Bale Starts At Date and Time is to remove the table fro...

Page 10: ...TableName See Section 6 4 NOTE 4 Number of Files to Keep The Baler is used to retrieve data from the LoggerNet server s data cache and save this information to disk on a remote computer It is expected...

Page 11: ...closed the temporary files are maintained When the Baler is reopened data storage to the temporary files will resume 6 2 Table Status and Messages Table Status tab You can review the status of the tab...

Page 12: ...ief pause the Baler will attempt to connect to the server and start baling when the application is started If a short cut to Baler is put in the Windows start up folder this will allow an automatic re...

Page 13: ...the Baler started in this manner will save its setting in a separate ini file This initialization file is saved to the directory specified by the pathname command line argument For example a shortcut...

Page 14: ...aces must be put inside quotation symbols NOTE 8 Importing Files into Other Applications All of the file formats except TOB are a variation of a comma delimited file Comma delimited files can easily b...

Page 15: ......

Page 16: ...a Corp CSC 11564 149th Street NW Edmonton Alberta T5M 1W7 CANADA www campbellsci ca dataloggers campbellsci ca Campbell Scientific Centro Caribe S A CSCC 300 N Cementerio Edificio Breller Santo Doming...

Reviews: