successfully.  This data collection method may create areas in the data cache 
where data is missing.  The discontinuity in the collected data is referred to as 
a hole. 

Baler’s default behavior is to bale on schedule regardless of holes.  If a hole is 
encountered in the LoggerNet cache, the resulting bale may have one or more 
missing records or the records in the bale may be out of order.  If records are 
missing from the bale, when LoggerNet eventually collects the hole, the 
records will be added to a subsequent bale.  They will, therefore, be found in a 
different bale than would be expected based on filenames.  Select Edit | Wait 
for Holes to force Baler to wait until holes are filled before continuing to bale. 

6.5  Command Line Options 

/WorkDir 

Multiple instances of the Baler can be run, and separate directories can be 
specified for the data files. This is done by setting up a separate shortcut for 
each instance to be run and using a command line option to start the Baler. The 
syntax is shown in the following command line: 

c:\Program Files\CampbellSci\Baler\Baler.exe (/WorkDir = 

pathname

)

 

where “

pathnam

e” is a valid directory path on the computer file system. Each 

instance of the Baler started in this manner will save its setting in a separate 
*.ini file. This initialization file is saved to the directory specified by the 

pathnam

e” command line argument. 

For example, a shortcut with the following as the command line in the “Target” 
window would start the Baler using the initialization file stored in the directory 
“ c:\Campbellsci\LoggerNet\Baler1” . 

c:\Program Files\Campbellsci\LoggerNet\Baler.exe   /WorkDir=c:\Campbellsci\LoggerNet\Baler1 

/r 

The /r option is used to change the name of the file that is created by the Baler 
from TableName_Date (e.g., OneMinute_2003_06_16_1200.dat) to 
Date_TableName (e.g., 2003_06_16_16_1200_OneMinute.dat).  The syntax 
for a Windows short cut would be: 

c:\Program Files\Campbellsci\Baler.exe /r 

7.  Advanced Options 

The user can specify a program to run 30 seconds after a baling event occurs. 
(The 30 second timer is reset after each baling event.  Therefore, the program 
will not be launched until 30 seconds have elapsed without a baling event.) 
This program can be an executable file or a batch file. To set up a program to 
be run, select Edit | Advanced Options and enter a file name in the File to 
Execute field. You can type in the program name directly or press the Browse 
button to the right of the field to display a standard file dialog box to search for 
a file.   If command line options are required for the executable, enter those 

Summary of Contents for Baler

Page 1: ...Baler Revision 12 09 C o p y r i g h t 2 0 0 3 2 0 0 9 C a m p b e l l S c i e n t i f i c I n c...

Page 2: ......

Page 3: ...copy of the software is an upgrade from a previous version you must possess a valid license for the earlier version of software You may continue to use the earlier copy of software only if the upgrad...

Page 4: ...dia or documentation Campbell Scientific will correct errors without charge by providing new media addenda or substitute pages If Campbell Scientific is unable to replace defective media or documentat...

Page 5: ...2 Allowing Remote Connections 1 2 Baler Settings 2 3 File Naming and Directory Structure 4 4 Number of Files to Keep 4 5 File Format 4 6 Baler Operation 5 6 1 Baling Controls 5 6 2 Table Status and Me...

Page 6: ...This is a blank page...

Page 7: ...the CD ROM drive and select the setup executable 3 This activates the Baler Installation Utility Follow the prompts on the screen to complete the installation An item is added to your computer s Start...

Page 8: ...e recommend that this feature be disabled unless it is essential that the data be made available to a remote computer running the Baler or other remote LoggerNet client This option can be enabled disa...

Page 9: ...g has begun for a table baling will continue on the same schedule even if baling is paused and then restarted The only way to change the Initial Bale Starts At Date and Time is to remove the table fro...

Page 10: ...TableName See Section 6 4 NOTE 4 Number of Files to Keep The Baler is used to retrieve data from the LoggerNet server s data cache and save this information to disk on a remote computer It is expected...

Page 11: ...closed the temporary files are maintained When the Baler is reopened data storage to the temporary files will resume 6 2 Table Status and Messages Table Status tab You can review the status of the tab...

Page 12: ...ief pause the Baler will attempt to connect to the server and start baling when the application is started If a short cut to Baler is put in the Windows start up folder this will allow an automatic re...

Page 13: ...the Baler started in this manner will save its setting in a separate ini file This initialization file is saved to the directory specified by the pathname command line argument For example a shortcut...

Page 14: ...aces must be put inside quotation symbols NOTE 8 Importing Files into Other Applications All of the file formats except TOB are a variation of a comma delimited file Comma delimited files can easily b...

Page 15: ......

Page 16: ...a Corp CSC 11564 149th Street NW Edmonton Alberta T5M 1W7 CANADA www campbellsci ca dataloggers campbellsci ca Campbell Scientific Centro Caribe S A CSCC 300 N Cementerio Edificio Breller Santo Doming...

Reviews: