background image

F568058

Operating Instructions

Air-to-Water Heatpump

Model No.
Indoor Unit

Outdoor Unit

 WH-SXC09D3E8

WH-UX09DE8

 WH-SXC12D9E8

WH-UX12DE8

© Panasonic HA Air-Conditioning (M) Sdn. Bhd. 2011. 
Unauthorized copying and distribution is a violation 
of law.

ENGLISH 

ENGLISH  

Before operating the unit, read these operating instructions thoroughly and keep them for future reference.

Before operating the unit, make sure the installation has been carried out correctly by authorized dealer correctly and 

precisely following the installation instructions given.

2 ~ 11

2 ~ 11

FRANÇAIS

FRANÇAIS

Avant d’utiliser l’appareil, lisez ce mode d’emploi dans son intégralité et conservez-le pour toute référence ultérieure.

Avant de faire fonctionner l’unité, assurez-vous que l’installation a été correctement réalisée par un revendeur agréé 

et dans le strict respect des consignes d’installation fournies.

12 ~ 21

12 ~ 21

ESPAÑOL 

Antes de utilizar la unidad, sírvase leer atentamente estas instrucciones de funcionamiento y conservarlas como 

futuro elemento de consulta.

Antes de operar la unidad asegúrese de que la instalación haya sido realizada correctamente por un instalador 

autorizado, siguiendo de forma correcta y precisa las instrucciones de instalación dadas. 

22 ~ 31

22 ~ 31

DEUTSCH 

Bevor Sie das Gerät in Betrieb nehmen, lesen Sie bitte diese Bedienungsanleitung aufmerksam durch und bewahren Sie 

sie für die künftige Verwendung auf.

Vor der Inbetriebnahme dieses Geräts ist sicherzustellen, dass die Montage durch einen autorisierten Händler 

fachgerecht entsprechend der Installationsanleitung durchgeführt wurde.

32 ~ 41

32 ~ 41

ITALIANO   

Prima di utilizzare l’unità si prega di leggere attentamente le istruzioni e di conservare questo opuscolo per potervi 

fare riferimento in futuro.

Prima di far funzionare l’unità, assicurarsi che l’installazione sia stata eseguita correttamente da un rivenditore 

autorizzato e seguendo precisamente le istruzioni date per l’installazione

42 ~ 51

42 ~ 51

NEDERLANDS  

Lees voor u het apparaat gebruikt deze gebruiksaanwijzing grondig en bewaar deze voor toekomstig gebruik. 

Controleer, voor u de unit in gebruik neemt, dat de installatie goed is uitgevoerd door een of

fi

 ciële dealer en dat dat 

nauwkeurig is gedaan volgens de verstrekte instructies voor de installatie.

52 ~ 61

PORTUGUÊS 

Antes de ligar a unidade, leia cuidadosamente este manual de utilização e guarde-o para futura referência.

Antes de colocar a unidade em funcionamento, ceritifque-se que a instalação foi feita correctamente por um 

fornecedor autorizado e que seguiu com precisão as instruções de instalação dadas.

62 ~ 71

E

ΛΛΗΝΙΚΆ

Προτού

 

θέσετε

 

τη

 

μονάδα

 

σε

 

λειτουργία

διαβάστε

 

προσεκτικά

 

αυτές

 

τις

 

οδηγίες

 

χρήσης

 

και

 

φυλάξτε

 

τις

 

για

 

μελλοντική

 

αναφορά

.

Πριν

 

θέσετε

 

σε

 

λειτουργία

 

τη

 

μονάδα

βεβαιωθείτε

 

ότι

 

η

 

εγκατάσταση

 

έχει

 

διεξαχθεί

 

κανονικά

 

από

 

εξουσιοδοτημένο

 

αντιπρόσωπο

ο

 

οποίος

 

έχει

 

ακολουθήσει

 

σωστά

 

και

 

πιστά

 

τις

 

δοθείσες

 

οδηγίες

.

72 ~ 81

БЪЛГАРСКИ

БЪЛГАРСКИ

   

Преди

 

да

 

задействате

 

климатика

прочетете

 

внимателно

 

инструкциите

 

за

 

употреба

 

и

 

ги

 

запазете

 

за

 

бъдещи

 

справки

.

Преди

 

да

 

използвате

 

устройството

 

се

 

уверете

че

 

монтажът

 

е

 

извършен

 

правилно

 

и

 

прецизно

 

от

 

оторизиран

 

дилър

като

 

са

 

спазвани

 

инструкциите

 

за

 

монтаж

.

82 ~91

82 ~91

0.2

0.4

0

0.3

0.1

MPa

TIMER

OUTDOOR

HEAT

SETTING
STATUS
PUMPDW

BOOSTER

QUIET

TANK

WATER OUTLET

C

C

OFF /ON

HEATER 

OPERATION

FORCE

HEATER 

ACTUAL

TIMER 1

MONTUEWEDTHU FRI SAT SUN

SOLAR REMOTE

NOT AVAILABLE

2 3 4 5 6

ON
OFF

COOL

Summary of Contents for WH-SXC09D3E8

Page 1: ... di utilizzare l unità si prega di leggere attentamente le istruzioni e di conservare questo opuscolo per potervi fare riferimento in futuro Prima di far funzionare l unità assicurarsi che l installazione sia stata eseguita correttamente da un rivenditore autorizzato e seguendo precisamente le istruzioni date per l installazione 42 51 42 51 NEDERLANDS Lees voor u het apparaat gebruikt deze gebruik...

Page 2: ...back in the limits To prevent personal injury injury to others or property damage please comply with the following Incorrect operation due to failure to follow instructions below may cause harm or damage the seriousness of which is classified as below WARNING WARNING This sign warns of death or serious injury CAUTION CAUTION This sign warns of injury or damage to property The instructions to be fo...

Page 3: ...e or electric shock Do not share the same power outlet with other equipment Do not operate with wet hands Do not over bend the power supply cord If the supply cord is damage it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard This unit is equipped with Residue Current Circuit Breaker RCCB It is strongly recommended to check the operat...

Page 4: ...m Status Check Mode Buttons 23 External Thermo Controller Connected Display 11 Heat Mode OFF ON Indicator 24 Outdoor Ambient Temperature Display 12 Cool Mode OFF ON Indicator 25 Water Outlet Temperature Display 13 Tank Mode OFF ON Indicator 26 Solar Display 27 Error Reset Button Notes The current day and time need to be set when The power is turned on for the first time After a long time has elaps...

Page 5: ... SET to confirm Function Operation Mode Actual Operation Description External Thermo Controller YES NO To set external thermo controller connection TANK Tank Connection YES NO To set tank connection SOLAR Solar Priority YES NO To choose the solar use for water tank heat up HEAT Heating Priority YES NO To choose the heat pump only use for Heating side during HEAT TANK mode HEAT Heating Heat up Inte...

Page 6: ...oor unit COOL TANK MODE In this mode the outdoor unit will provide cooling capacity to the indoor unit Indoor unit will control booster heater in sanitary tank QUIET TO ENJOY QUIET ENVIRONMENT This operation reduces outdoor unit noise In this condition it may cause decrease in heating cooling capacity HEATER TO ENABLE THE BACKUP HEATER The backup heater provides extra heating capacity during cold ...

Page 7: ...other parameters Operation Mode Parameter Description HEAT Low outdoor ambient set temperature 15 C 15 C HEAT High outdoor ambient set temperature 15 C 15 C HEAT Water outlet set temperature at low outdoor ambient temperature 25 C 55 C HEAT Water outlet set temperature at high outdoor ambient temperature 25 C 55 C HEAT OFF Set temperature for turning OFF heating operation 5 C 35 C HEATER ON Outdoo...

Page 8: ...eps 4 to 7 to set programs 2 to 6 During timer setup if no button is pressed within 30 seconds or if the SET button is pressed the setting at that moment is confirmed and timer setup is ended Add Modify timer Repeat the steps above Disable timer Press TIMER then press CANCEL Enable timer Press TIMER then press SET Check timer 1 Press TIMER 2 Press or until your desired day is shown press SELECT to...

Page 9: ...e the unit gently with a soft dry cloth EXTERNAL FILTER Please clean the external filter at least once a year Fail to do so might cause filter clogged consequent system breakdown Please consult authorized dealer OUTDOOR UNIT Do not obstruct the air inlet and air outlet vents it may cause low performance or breakdown Please remove obstacles to assure the ventilation During winter please clean and r...

Page 10: ...rm System cannot get warm instantly Due to the nature of the heatpump system it may take some time to heat up the water if the unit is operated from cold start Operation starts after power resumes Unit is operates under auto restart function Check the following before calling for servicing Check the following before calling for servicing SYMPTOM SYMPTOM CHECK CHECK Heating cooling operation is not...

Page 11: ...n health and the environment which could otherwise arise from inappropriate waste handling For more information about collection and recycling of old products please contact your local municipality your waste disposal service or the point of sale where you purchased the items Penalties may be applicable for incorrect disposal of this waste in accordance with national legislation For business users...

Page 12: ...Panasonic Corporation Website http panasonic net Pursuant to at the directive 2004 108 EC article 9 2 Panasonic Testing Centre Panasonic Service Europe a division of Panasonic Marketing Europe GmbH Winsbergring 15 22525 Hamburg F R Germany ...