7
9
Booster Heater
To activate or deactivate the water tank’s booster heater.
Note: If NO is selected, menu 10 is skipped.
YES
YES
NO
10
Booster Heater Delay Timer
To delay time for the booster heater to activate while the system is
heating up the water tank.
1 hour
20 minutes ~
1 hour 35 minutes
• Do not use the system during sterilisation in order to prevent scalding with hot water, or overheating of shower.
• Ask an authorised dealer to determine the level of sterilisation function field settings according to the local laws and
regulations.
11
Sterilisation
To sterilise the water tank, if required.
Note: If NO is selected, menus 12 to 14 are skipped.
YES
YES
NO
12
Sterilisation Day & Time
To set timer for sterilisation.
(Only once a week. Operates even under a standby condition)
Monday
12:00
Monday ~ Sunday
0:00 ~ 23:50
13
Sterilisation Temperature
To set the temperature of sterilisation.
70 °C
40 °C ~ 75 °C
14
Continuation of Sterilisation
To maintain heating temperature in order to complete the
sterilisation.
10 minutes
5 minutes ~
1 hour
15
Base Pan Heater
To select whether or not to connect to the optional base pan
heater.
Note: If NO is selected, menu 16 is skipped.
NO
YES
NO
16
Base Pan Heater type
Type A - The base pan heater activates only during deice
operation.
Type B - The base pan heater activates when outdoor ambient
temperature is 5 °C or lower.
A
A
B
17
Dry Concrete
During construction to dry the concrete under a preset
temperature.
Do not use this menu for any other purposes and in period other
than during construction (Refer to information page).
-
1 day ~ 99 days
User
Remote control preparation
1
Press
.
2
Press or to set the current day.
3
Press to confirm.
4
Repeat steps
2
and
3
to set the current time.
■
Note:
• The current day and time need to be set in cases below:
- When the power is turned on for the first time.
- A long time has elapsed since the power was turned on the
last time.
• The current time that has been set will be the standard time for
all the timer operations.
Caution Indicator (Tank Temperature above 60 °C)
Dealer
Operation/settings to be done only by the authorised dealer/specialist.
User
Operation/settings to be done by the authorised dealer/specialist or user.
English
To
adjust initial settings