Installation and Operating Instructions

Video Intercom System for Apartment Complexes

Model No.    

VL-V900 and VL-V700 Series 

VL-V900

VL-V700

VL-V701

VL-V702

VL-V703

Thank you for purchasing a Panasonic product.
Please follow all instructions in this document and save it for future reference.

This system is an auxiliary system; it is not designed to provide complete protection from property loss.
Panasonic will not be held responsible in the event that property loss occurs while this system is in operation.

Summary of Contents for VL-V900

Page 1: ...2 VL V703 Thank you for purchasing a Panasonic product Please follow all instructions in this document and save it for future reference This system is an auxiliary system it is not designed to provide...

Page 2: ...Wiring Connections 26 4 6 Connecting other devices 37 4 7 Basic settings 38 5 Programming 5 1 Programming overview 39 5 2 PC programming 39 5 3 Lobby station programming 45 5 4 Telephone programming...

Page 3: ...d to the control box and up to 6 lobby stations can be connected to each extension box Easy to configure and maintain R System settings can be configured in advance using a computer and uploaded on si...

Page 4: ...boxes Lift Controller up to 15 3 branches x 5 lift controllers Room units up to 560 20 room units x 28 distribution boxes PBX 1 Terminal up to 4 Emergency Terminal 1 Lift up to 3 Lobby Station up to 3...

Page 5: ...l Box 1 4 distribution box branches 3 lift controller branches Lobby station 1 group Lobby station 2 group Lobby station 3 group Extension Box 1 3 x 6 x 6 x 6 1 When the lobby stations are connected t...

Page 6: ...ower cables firmly all the way into the terminals If the cables are not inserted all the way heat may be generated R If the wiring is outdoors use a protection tube and a surge protector R If the wiri...

Page 7: ...ysically unusable R Protect user information when disposing of the control box or lobby station Remove the SD memory card from the control box Render it physically unusable and dispose of it Use the s...

Page 8: ...5 Please visit here http www ptc panasonic eu erp Click Downloads Energy related products information Public Power consumption in networked standby and guidance are mentioned in the web site above Aut...

Page 9: ...1 Power supply unit VL PS240 1 Screw for mounting the power supply unit 4 mm 40 mm 2 Cable binder for securing the AC and DC cables 2 3 1 2 Control Box Item Quantity Screw for mounting the box 3 8 mm...

Page 10: ...ounting the power supply unit 4 mm 40 mm 2 Cable binder for securing the AC and DC cables 2 3 1 4 Lift Controller Item Quantity Screw for mounting the box 3 8 mm 20 mm 2 Cable binder for securing the...

Page 11: ...nal items The following items are also required for installation and are not included Power cables Used to connect power supply units to lobby stations the control box distribution boxes and lift cont...

Page 12: ...OUT L1 L2 C1C2 S1 S2 H I J A G F B C D E A Reset button Used when restarting the lobby station B Function button For internal use only C Power switch D Cable release button for DC power supply cable E...

Page 13: ...L Power switch M Cable release button for DC power supply cable N Connection terminals for DC power supply 3 2 3 Distribution Box K J F G L N C D E A B H I M A Power indicator POWER See 5 10 2 Distri...

Page 14: ...hen restarting the lift controller I Function button For internal use only J Power switch K Cable release button for DC power supply cable L Connection terminals for DC power supply 3 2 5 Extension Bo...

Page 15: ...y unit is for indoor use only Display Approx 10 92 cm 4 3 inches monochrome display white backlit LCD Display the date room number inputted by visitors how to use name of residents and custom item Ins...

Page 16: ...setting HH MM DD MM YYYY R Download upload the name of residents room number and monitor setting R Output the system configuration data R Estimate the status of equipment in the system R Operation set...

Page 17: ...tion only Installation method Wall mount or attach to DIN rail External material ABS flame retardant ABS resin Connectivity To main monitor Number of connectable stations 20 Wire 1 pair PE insulation...

Page 18: ...depth Approx 210 108 5 52 5 excluding protruding sections Mass weight Approx 350 g Operating environment Ambient temperature approx 10 C to 50 C Ambient temperature for power supply unit approx 0 C to...

Page 19: ...ng off the wall Avoid installing onto low strength walls such as gypsum board ALC autoclaved lightweight concrete concrete block or veneer less than 18 mm thick walls 4 2 Installing the Power Supply U...

Page 20: ...N m 4 6 kgf cm CAUTION R Insert the AC and DC cables firmly all the way into the terminals If the cables are not inserted all the way heat may be generated 4 Use the cable binders accessory to secure...

Page 21: ...a risk of malfunction or communication disturbances Places where vibration impact or echoing occurs Places near a high concentration of dust hydrogen sulphide ammonia sulphur or noxious fumes Places w...

Page 22: ...mm Approx Approx Approx 1500 mm Centre of the Camera lens 1600 mm 700 mm Top view view when looking from above Approx 500 mm Approx 170 Note R Install the lobby station so that the lobby station is n...

Page 23: ...camera E Wires from control box F Wires from access controller G Wires from electric lock H Wire release button I Connection terminal R To connect the DC cable from the power supply unit press the ca...

Page 24: ...R If an error is displayed the lobby station will still be registered to the system 4 4 Installing the Control Box Distribution Box Lift Controller Extension Box The following 2 methods can be used fo...

Page 25: ...Mounting on a DIN rail Mount the control box on the DIN rail A using the hooks B B A Attaching directly to a wall Attach the unit to the wall securely using the 2 supplied screws A A 25 4 Installation...

Page 26: ...s fully into the connection terminals After inserting the wires pull slightly on each wire to make sure it is firmly connected Basic system example NP Non polarised Distribution Box 1 Lobby Station 1...

Page 27: ...R3 IN1 9 10 IN2 IN3 11 12 IN4 P1 13 P2 NP 1 2 D1 D2 3 4 D3 D4 5 6 R1 R2 7 8 R3 IN1 9 10 IN2 IN3 11 12 IN4 P1 13 P2 NP NP NP POWER SUPPLY UNIT DC IN NP 1 2 D1 D2 3 4 D3 D4 5 6 R1 R2 7 8 R3 IN1 9 10 IN2...

Page 28: ...1 Main Monitor Door Station Distribution Box up to 28 Repeater up to 4 Lobby Station up to 18 Room unit up to 560 Extension Box 3 Control Box 1 NP Non polarised NP NP NP Lift Controller up to 3 for Bi...

Page 29: ...C IN NP POWER SUPPLY UNIT DIP SW 1 ON 1 0 F 19 F Lift 1 DC IN NP POWER SUPPLY UNIT DIP SW 5 ON 5 80 F 99 F NP Lift 1 DC IN NP POWER SUPPLY UNIT DIP SW 1 ON 1 0 F 19 F Lift 2 DC IN NP POWER SUPPLY UNIT...

Page 30: ...NP Non polarised DC IN NP POWER SUPPLY UNIT NP Lift Controller up to 3 DC IN NP POWER SUPPLY UNIT DIP SW 1 ON 1 DC IN NP POWER SUPPLY UNIT DIP SW 1 ON 2 0 F 99 F NP DC IN NP POWER SUPPLY UNIT DIP SW...

Page 31: ...m Power supply unit AC power source 1 2 mm 17 AWG No requirement 2 mm 12 AWG Lobby station Electric lock 0 5 mm 24 AWG According to specification of connected device 1 2 mm 17 AWG Note the following w...

Page 32: ...settings The distribution box has 3 types of switches that determine how it operates DIP switches DIP switches determine the distribution box number 1 7 of each distribution box in the branch Terminat...

Page 33: ...N OFF off off G 1 2 3 4 5 6 7 8 ON OFF off on 1 Each DIP switch setting can only be used one time per branch The number 8 switch must always be set to the off position Only one DIP switch is set to th...

Page 34: ...nly one DIP switch is set to the on position All others are set to the off position 2 In repeater mode the repeat switch of one distribution box in the branch is set to the on position All others are...

Page 35: ...r 8 DIP switch determines whether connections are normally open or normally closed Note R After you have set the DIP switches you must also configure the system to use relay signalling or binary signa...

Page 36: ...he off position or normally closed switch is in the on position 4 5 6 Extension box switch settings The extension box s DIP switches are only used when configuring settings for the extension box and l...

Page 37: ...and installed to the control box Download information is available at the following web site http panasonic net pcc support intercom v900 Refer to 5 8 Upgrading the system software for digital PBXs P...

Page 38: ...ion box switch settings Page 32 R For lift controllers DIP switch settings Configure using the device s DIP switches 4 5 5 Lift controller DIP switch settings Page 35 Lift access permissions for each...

Page 39: ...rogramming See 5 8 Upgrading the system software for digital PBXs Page 57 for information about upgrading the system software R After using the setup tool to communicate with the system restart the co...

Page 40: ...saved in CSV format Prepare the data Allows you to choose whether you want to create new configuration files use existing configuration files or download the current data from the system s devices Lo...

Page 41: ...OK displayed in the right side of the Load and edit the data section 6 In the Upload the data to device section select the devices that you want to upload the data to and then click Upload Note R See...

Page 42: ...he control box s date and time 1 Start the setup tool 2 In the Time and date settings section click Time and Date Settings Control Box 3 Set the date and time and then click Set to Control Box 5 2 8 C...

Page 43: ...cations of the lift 0 RELAY 1 BINARY 0 RELAY Lift Signal Time After a visitor is admitted this setting determines the amount of time that the visitor can use the lift to visit the corresponding floor...

Page 44: ...0 characters max uppercase letters only Lobby Station 1 3 General settings Parameter Description and available settings Default Door Key Open Time Determines the amount of time the door stays open If...

Page 45: ...ES 0 NO Wide Zoom Determines whether camera images are displayed in wide mode or in zoom mode when monitoring begins 0 WIDE 1 ZOOM 0 WIDE Zoom Position Determines the camera zoom position 1 UPPER LEFT...

Page 46: ...uired to use the lobby station programming 1 Press M N enter the access code M N R The default access code is 123456 2 Select SET ACCESS CODE M N 3 Enter the desired 6 digit code M N 4 Press M N 5 3 1...

Page 47: ...RNAL IN is set to YES 00 CLOSE SET CAMERA CAMERA CONNECTION Tells the system whether a camera is connected or not 00 NO 01 YES 00 NO CAMERA NAME Determines the camera name 01 CAMERA 02 RECEPTION 03 GA...

Page 48: ...90 SEC 02 60 SEC 03 30 SEC 00 180 SEC TALK TIME OUT Determines the amount of time that passes when talking before the standby screen is displayed 00 90 SEC 01 60 SEC 02 30 SEC 03 180 SEC 04 300 SEC 00...

Page 49: ...will assign Feature number Description 0 Emergency terminal 1 Terminal 1 2 Terminal 2 3 Terminal 3 4 Terminal 4 3 Enter the extension number of the terminal that you want to assign press R Example For...

Page 50: ...system 1 Dial the extension number assigned to the control box 2 Enter a feature number to specify which terminal will be deleted Feature number Description 0 Emergency terminal 1 Terminal 1 2 Termina...

Page 51: ...control box Note R If you press the settings will be saved in the main monitor only and the main monitor will restart To save the settings in the control box press When programming the VL MW251 1 Pres...

Page 52: ...obby station c Press when finished R Repeat the above procedure for LIFT 2 and LIFT 3 7 Confirm the displayed settings R Press to go back and enter the desired settings again 8 Press to check for a du...

Page 53: ...wing parameters are available when using main monitor programming Note R You can also use PC programming to configure these settings for each main monitor Parameter names are slightly different when u...

Page 54: ...o be configured page 56 2 PC setup tool Start the setup tool and configure the required Room settings and General settings R Refer to page 39 for more information about PC programming 3 PC setup tool...

Page 55: ...set to the off position For a list of DIP switch settings see page 56 1 DIP switch setting of extension box Set the DIP switches to the settings shown under A 1st lobby station 1 2 PC setup tool Load...

Page 56: ...tch 1 2 3 4 5 6 7 8 ON OFF off 5 7 System log You can insert an SD into the control box and use it to log system event information The following information can be logged Caller and called party infor...

Page 57: ...for digital PBXs must be downloaded and installed to the control box Download new system software 1 Download the system software update file R Refer the information on the following web site http pan...

Page 58: ...connection check completed Off Lit Reset in progress Flashing quickly Off Reset completed Off Lit Error Duplicate distribution box number found Off Flashing slowly 5 10 2 Distribution box indicators C...

Page 59: ...on box indicators Category Meaning POWER green ACCESS red Normal operation Idle Lit Off Call or monitoring in progress Lit Lit Error DIP switch 4 6 7 or 8 is in the on position Lit Flashing slowly 59...

Page 60: ...limited to 10 minutes 6 2 Lobby station operations 6 2 1 Calling a resident Entering a room number 1 Enter the resident s room number 2 Press M N to call Searching by first letter of the name 1 Press...

Page 61: ...ure you want to operate Feature number Assignment 000 Open the entrance door s 2 digit floor number Open the entrance door s and allow the lift to visit the specified floor Repeat the voice guidance R...

Page 62: ...all calls time out and are disconnected after a programmed amount of time 60 The lobby station screen is blank R The lobby station has not detected the visitor Lobby stations feature a motion sensing...

Page 63: ...o the camera Connect the cable to the camera R Power is not connected to the camera Check the power connection and connect power to the camera R The signal format PAL or NTSC used in incorrect Match t...

Page 64: ...dry cloth For excessive dirt wipe the product with a slightly damp cloth Important R Do not use any cleaning products that contain alcohol polish powder powder soap benzine thinner wax petroleum or b...

Page 65: ...65 Notes...

Page 66: ...66 Notes...

Page 67: ...67 Notes...

Page 68: ...Panasonic Corporation 2015 1006 Oaza Kadoma Kadoma shi Osaka 571 8501 Japan http www panasonic com PNQP1226WA C1115HH3037...