Installation
Note:
L
The measurements and angles are for reference purposes and may vary depending on the environment.
L
If a strong light is shining on the main unit, the visitor’s face may not be distinguishable.
Do not place the main unit in the following locations.
– Where most of the background is the sky.
– Where the background is a white wall, and direct sunlight will reflect off it.
– Where direct sunlight will shine on the main unit.
L
Do not place the main unit in the locations where echoing occurs, causing the unit to beep frequently.
L
Make sure the rear of the main unit is not subject to water.
Before installation
Important:
L
To avoid malfunction or communication disturbances, do not install the lobby station in the following locations:
– Places where vibration or any other kind of impact occurs.
– Places near hydrogen sulfide.
L
Do not place other devices or obstacles in the area around
the main unit shown in the figure.
L
Do not install the power supply unit in the following places:
– Places where the power supply unit may be splashed with water or
chemicals.
– Places where there is a high concentration of dust, or high humidity.
Side view when the camera is
installed lower than the standard
position, and facing upwards at 15°.
Example: Installation height is 980 mm.
1330 mm
1810 mm
Center of
main unit
66° 650 mm
Image
range
1160 mm
500 mm
Top view
Image range:
960 mm
500 mm
87°
Side view when the camera is facing
forwards at 0° (de
fault).
Example: Installation height is 1330 mm
(standard position).
Installation position of the main unit and camera range
Side view when the camera is installed on a pedestal
tilted at 60°, and facing forwards at 0° (de
fault)
.
Example: Installation height is 1100 mm.
5 mm 5 mm
15 mm
20 cm
Main
unit
PP
PP
PP
PP
PP
,PDJH
UDQJH
&HQWHURI
PDLQXQLW
Installing on a vertical flat wall
1690 mm
980 mm
710 mm
500 mm
980 mm
Image
range
Center of
main unit
66°
Installing on a tilted pedestal
L
Do not install on a pedestal tilted at less than 45°.
Side view when the camera is installed on a pedestal
tilted at 45°, and facing downwards at 5°.
Example: Installation height is 1120 mm.
PP
PP
PP
PP
PP
,PDJH
UDQJH
&HQWHURI
PDLQXQLW
The camera angle can be adjusted using the camera angle control lever on the rear of the upper cabinet (page 8), so
that the image range can be changed.