Panasonic VL-MWD273 Installation Manual Download Page 2

2

For your safety

To prevent severe injury and loss of life/
property, read this section carefully 
before using the product to ensure 
proper and safe operation of your 
product.

Preventing fire, electric shock and 
short circuits

R

Leave installation work to the 
dealer. Installation work requires 
technique and experiences. Failure 
to observe this may cause fire, 
electric shock, injury, or damage to 
the product. Consult the dealer.

R

Electrical connection work should 
be performed by certified personnel 
only. Certification is required for 
performing electrical connection 
work. Consult your dealer.

R

Use only the specified power supply 
unit and AC cable.

R

Do not attempt to disassemble or 
modify this product. Contact an 
authorised service centre for repairs.

R

Never install wiring during a lightning 
storm.

R

Do not connect non-specified devices.

R

Do not connect a power cable to a 
terminal that is not specified in this 
guide.

R

When opening holes in walls for 
installation or wiring, or when securing 
the power cable, make sure you do not 
damage existing wiring and ductwork.

R

Do not make any wiring connections 
when the power supply is turned on.

R

Do not use the supplied power supply 
unit for outdoor installations (it is for 
indoor use only).

R

Do not install the main monitor/
extension monitor in the following 
places:
– Places where the main monitor/

extension monitor may be splashed 
with water or chemicals.

– Places where there is a high 

concentration of dust, or high 
humidity.

R

Do not perform any actions (such as 
fabricating, twisting, stretching, 
bundling, forcibly bending, damaging, 
altering, exposing to heat sources, or 
placing heavy objects on the power 
cable) that may damage the power 
cable. Using the product with a 
damaged power cable may cause 
electric shock, short circuits, or fire. 
Contact an authorised service centre 
for repairs.

R

When existing chime wires are used, it 
is possible that they contain AC 
voltage.
Contact an authorised service centre.

Preventing accidents and injuries

R

Do not install or use the product in 
health care facilities if any regulations 
posted in the area instruct you not to 
do so. Hospitals or health care 
facilities may be using equipment that 
could be sensitive to external RF 
(radio frequency) energy.

R

Do not install or use this product near 
automatically controlled devices such 
as automatic doors and fire alarms. 
Radio waves emitted from this product 

WARNING

273_ig.book  Page 2  Friday, April 28, 2017  9:46 AM

Summary of Contents for VL-MWD273

Page 1: ... attempting to connect or operate this product please read the label on the rear of the doorphone and the main monitor extension monitor R Please read this guide carefully and install the product safely and correctly by following the instructions Carefully read the information found in the section titled For your safety in particular R Only use attachments accessories specified by the manufacturer...

Page 2: ... supply is turned on RDo not use the supplied power supply unit for outdoor installations it is for indoor use only RDo not install the main monitor extension monitor in the following places Places where the main monitor extension monitor may be splashed with water or chemicals Places where there is a high concentration of dust or high humidity RDo not perform any actions such as fabricating twist...

Page 3: ...ight concrete concrete block or veneer less than 18 mm thick walls Supplied accessories for installation Important R You will need the following additional items to install and configure the doorphone and the main monitor extension monitor CAUTION For the doorphone 1 Mounting base 1 Screw 4 4 mm 12 mm Screw 2 3 8 mm 20 mm Name plate 2 incl 1 spare Hex wrench 1 For the main monitor extension monito...

Page 4: ...ion location condensation may form on the doorphone s lens cover This may cause images to become obscured Condensation will dissipate as the temperature rises For the main monitor extension monitor R Install the main monitor away from electronic appliances such as TVs radios personal computers air conditioners boiler control panels with intercom home security equipment wireless devices or digital ...

Page 5: ...used when a VL V900 and VL V700 series Video Intercom System for Apartment Complexes is used Make sure to connect emergency terminals to the IN1 IN2 terminals Make sure to connect doorbells to the IN3 IN4 terminals A doorbell and doorphone 2 cannot be used together 4 VL MWD273BX VL MWD273ML models only 5 VL SWD273AZ VL SVD273AZ VL MWD273AZ Use only the supplied AC cable D1D2 S1 S2 Electric lock El...

Page 6: ...erminal IN1 IN2 IN3 IN4 Input method No voltage contact Open circuit voltage between terminals DC 7 V or less Detection definite time 0 1 second or more Short circuit between terminals 5 mA or less Resistance value make 500 Ω or less break 15 KΩ or more Wiring run Wire type 1 Diameter Length Max Doorphone Main monitor Extension monitor 2 ø 0 65 mm 22 AWG 100 m ø 1 0 mm 18 AWG 130 m ø 0 5 mm CAT 5 ...

Page 7: ...ain monitor Operating Instructions of the Video Intercom System R Connection for VL V900 and VL V700 series Video Intercom System for Apartment Complexes Connect terminal D1 D2 on the main monitor with terminal D1 D2 on the VL V701 Distribution Box Note R For information about connections refer to the documentation of the VL V590 or VL V900 and VL V700 series MAIN MONITOR D1 D2 D3 D4 Ml 1 Ml 2 MO ...

Page 8: ...mera lens When set to wide default Units mm A Image range B Approx 110 C Centre of doorphone D Approx 1450 E Approx 500 F Approx 2150 G Approx 1400 H Approx 750 I Approx 170 J Approx 500 When set to zoom R You can use the main monitor s Zoom position settings setting to select the desired area visible when zooming Refer to the following and configure the main monitor E G H I J A view when looking ...

Page 9: ... default A Image range B Approx 55 C Center of doorphone D Approx 1450 E Approx 500 F Approx 1700 G Approx 500 H Approx 1200 A Image range Approx 900 B Approx 500 C Approx 85 Down Right A Image range B Approx 55 C Center of doorphone D Approx 1450 E Approx 500 F Approx 1420 G Approx 500 H Approx 920 A Image range Approx 900 B Approx 500 C Approx 170 D Approx 85 C F B A E D G H B C D A C F B A E D ...

Page 10: ...iring materials 1 Attach the mounting base B accessory to the wall securely R Install the mounting base on a vertical flat wall A Screws accessory 2 C Wire locally procured D 83 5 mm 1 To prevent dew condensation fill a hole for wiring as much as possible 2 Use a hex wrench A accessory to loosen screw A B and remove the front panel C of the doorphone A 2 mm hex wrench A B C D 1 When using mounting...

Page 11: ...cessory 4 5 Attach the name plate A accessory to the doorphone and use screw A B to secure the front panel R Write the name on the name plate as needed B Recommended torque 0 35 N m 3 6 kgf cm A B Recommended torque 0 5 N m 5 1 kgf cm Maximum torque 0 7 N m 7 1 kgf cm A B A When using mounting box option Model No VL MB554 Attach the doorphone to the flush mounting box A Screws accessory 4 A A B 27...

Page 12: ...tions Make sure that there are no bare wires exposed outside the product L AC cable binder hole M DC cable binder hole 1 Strip the AC DC cables as follows AC cable A C DC cable B C 2 Remove the screws D and then remove the cable covers E 3 Connect the AC cable F to the AC IN terminal J DC cable H to the DC OUT terminal K on the top and bottom of the power supply unit and then secure the wires by t...

Page 13: ...ly procured A 25 mm B7 mm 1 Make sure that there are no bare wires exposed outside the product K DC cable binder hole 1 Strip the DC cables as follows DC cable A B 2 Remove the screws C and then remove the cable cover D 3 Connect the AC cable E accessory to the AC IN connector I on the top of the power supply unit Next connect the DC cable G locally procured to the DC OUT terminal J on the bottom ...

Page 14: ...cket in the location shown below C Main monitor extension monitor installation position D 121 5 mm E 58 mm Installing the main monitor extension monitor 1 Attach the mounting bracket A to the wall securely R Install the mounting bracket on a vertical flat wall B C Screws accessory D Hole in wall E 60 mm F 83 5 mm G 7 mm H 50 mm 2 Connect the DC cable and wires R Connect the wires correctly accordi...

Page 15: ... monitor extension monitor to the mounting bracket 3 1 Line up the tab on the bottom of the bracket with the groove on the main monitor extension monitor 3 2 Line up the tab on the top of the bracket with the groove on the main monitor extension monitor and push the main monitor extension monitor down until it is secure G H F I Notes about electrical wiring Make sure not to pinch the wires as show...

Page 16: ... Panasonic Corporation 2017 PNQX8466ZA C0417MM0 1006 Oaza Kadoma Kadoma shi Osaka 571 8501 Japan http www panasonic com 273_ig book Page 20 Friday April 28 2017 9 46 AM ...

Reviews: