51
VL-SVN511BX/VL-SVN511CX/VL-SVN511CX1
10.1.4.3. Advance settings Mode
This setting is optional settings for e-mail transmission.
Entering Advance settings Mode:
1. Turn AC Power “ON”, while pressing [OFF] button, [TALK] button and [F1] at the same time, about 5 seconds or more.
Function Setting List
[ ] : It is the contents of the initial value.
In order to exit Advance settings Mode:
1. Press the [OFF] button.
10.1.4.4. Apartment mode
This setting is used connect the Main Monitor Station to “Lobby Station” or “Video Intercom System for Apartment Complexes”.
Note: When this mode is selected, all data and images will be initialize.
Entering Advance settings Mode:
1. Turn AC Power “ON”, while pressing [OFF] button, [TALK] button and [F2] at the same time, about 5 seconds or more.
Function Setting List
[ ] : It is the contents of the initial value.
In order to exit Apartment Mode:
1. Press the [OFF] button.
Function Menu
Settings and Overview
SMTP authentication type
Selection: [Auto], CRAM-MD5, PLAIN, LOGIN
If you can not send mail to SMTP authentication, depending on the configuration of the server, it can
be resolved by changing the setting to such as "PLAIN" and "LOGIN".
TLS version
Selection: Version 1.0, [Version 1.2]
If you can not send e-mail due to the version mismatch of the security type (TLS), and depending on
the setting of the mail server, it can be resolved by changing the setting to such as “version 1.0” and
“version 1.2”.
Function Menu
Settings and Overview
House mode
Selection: Display, [Don't display]
Display: Use only when connecting the “Lobby Station” (VL-V590) in House mode.
Apartment mode
It is used when connecting to the “Video Intercom System for Apartment Complexes”.
It switches automatically to Apartment mode in the communication settings from the PC tool.
Please use when switching manually.
Summary of Contents for VL-MVN511BX
Page 20: ...20 VL SVN511BX VL SVN511CX VL SVN511CX1 Reference Refer to Image Signal in Signal Route P 32 ...
Page 21: ...21 VL SVN511BX VL SVN511CX VL SVN511CX1 Reference Refer to AM Signal in Signal Route P 32 ...
Page 23: ...23 VL SVN511BX VL SVN511CX VL SVN511CX1 8 2 1 Defect of the Main Monitor Station Power Supply ...
Page 24: ...24 VL SVN511BX VL SVN511CX VL SVN511CX1 Defect of the Main unit power supply ...
Page 25: ...25 VL SVN511BX VL SVN511CX VL SVN511CX1 ...
Page 33: ...33 VL SVN511BX VL SVN511CX VL SVN511CX1 ...
Page 34: ...34 VL SVN511BX VL SVN511CX VL SVN511CX1 ...
Page 74: ...74 VL SVN511BX VL SVN511CX VL SVN511CX1 15 1 2 Door Station ...
Page 75: ...75 VL SVN511BX VL SVN511CX VL SVN511CX1 15 1 3 Power Supply Unit ...
Page 76: ...76 VL SVN511BX VL SVN511CX VL SVN511CX1 15 1 4 Relay Box ...
Page 78: ...78 VL SVN511BX VL SVN511CX VL SVN511CX1 15 1 5 2 VL SVN511CX VL SVN511CX1 ...