5. General information
10
5. General information
General information
5.1 Cleaning
Wipe the product with a soft, dry cloth.
For excessive dirt, wipe the product with a moist cloth.
Important:
R
Do not use any cleaning products that contain
alcohol, polish powder, powder soap, benzine,
thinner, wax, petroleum, or boiling water. Also
do not spray the product with insecticide, glass
cleaner, or hair spray. This may cause a change
in colour or quality of the product.
5.2 Specifications
Main monitor
Power source
Supplied by the bus line (from a
distributor or a lobby station)
Input power
VL-MV10EX1/VL-MV10SX:
Standby: 10 V, 2 mA
Operating: 22 V, 180 mA
VL-MV10EX2:
Standby: 10 V, 2 mA
Operating: 22 V, 250 mA
Dimensions
(mm) (height
×
width
×
depth)
Approx. 149
×
130
×
25
(excluding protruding sections)
Mass (weight)
Approx. 270
g
Operating
environment
Ambient temperature: approx.
0
°
C to +40
°
C
Relative humidity (non-
condensing): up to 90 %
Display
Approx. 8.9 cm (3.5 inches
colour display)
Talking method
Hands-free
Installation
method
Wall mount (mounting bracket
supplied)
Induction loop
system for
hearing aid
users (VL-
MV10EX2 only)
EN 303 348
Frequency: 100 Hz - 5 kHz; RF
transmission power: 1,005 mA/
m (max.)
prj_4365-as_is.book Page 10 Monday, August 27, 2018 6:03 PM