24
2. Remove the cabinet assy and the plasma panel fastening
screws (
×
7 ).
3. For leaving the plasma panel from the front frame, pull the
bottom of the cabinet assy forward, lift, and remove.
4. Remove the spacers and spacer rings (
×
6).
5. Remove the BC hook (left, right).
Caution:
• Please confirm the installation of BC hook (Left, right),
Spacer and Spacer Ring when you exchange the Plasma
Panel, and install BC hook (Left, right), Spacer and Spacer
Ring in an original installation place after exchanging the
Plasma Panel.
7.21. Replace the plasma panel (fin-
ished)
1. Place the new plasma panel (finished) on the flat surface
of the table (covered by a soft cloth), with the plasma
panel surface facing downward.
2. Attach the C1-Board and the C2-Board, connect the flexi-
ble cables (
×
16) from the Plasma panel to the C1-Board
and the C2-Board, and fit the flexible cable holders.
3. Attach the Hooks (left, right) and fit the stand brackets (L,
R) to the new plasma panel.
4. Place the plasma panel section on the servicing stand.
5. Attach the cabinet assy and each P.C.Board and so on, to
the new plasma panel.
*When fitting the cabinet assy, be careful not to allow
any debris, dust or handling residue to remain
between the front glass and plasma panel.
Summary of Contents for Viera TH-37PV8PA
Page 7: ...7 3 3 Applicable signals ...
Page 17: ...17 6 4 No Picture ...
Page 34: ...34 ...
Page 36: ...36 10 3 Wiring 37 inch ...
Page 37: ...37 11 Schematic Diagram 11 1 Schematic Diagram Note ...
Page 108: ...108 13 1 2 Packing ...
Page 109: ...109 13 1 3 Mechanical Replacement Parts List ...
Page 115: ...115 13 2 Electrical Replacement Parts List 13 2 1 Replacement Parts List Notes ...