Slide # 45
Troubleshooting TCON Problems Continued
Troubleshooting a dead TCON board
When the TCON board completely fails, data communication data between IC8001 and the TCON IC
will come to an end. The television will shut down and the power LED will blink 9 times, indicating the
failure of the TCON.
When there is no error code, the usual approach is for the technician to replace the A-board. Once it
is determined that the A board is not the fix, one can conclude with a degree of certainty that the
problem is the TCON board.
Avoiding wrong board replacement
One way to determine the location of the fault is
to loosen the LVDS connector at the TCON
board while the unit is turned on. Unlock the
connector and gently rock the cable in and out of
the socket while observing the screen for any
sign of noise. The response may be gentle white
fl
ashes, intermittent colored lines, or a screen full
of random patterns. A TCON board that has
completely failed will not generate any type of
symptom on the screen.
Another method to rapidly diagnose the TCON is
to apply heat and/or cool with hot air devices or
circuit coolant and watch for random noise to
appear on the screen.
A21
TC05
LVDS
CONNECTOR
Summary of Contents for Viera TC-L42D2
Page 25: ...Slide 25 Power on Part 1_ All Except D2 ...
Page 27: ...Slide 27 Power On Part 2_ All Series Except D2 ...
Page 30: ...Slide 30 Power On Part 2_ D2 series ...
Page 33: ...Slide 33 TC L32U22 Inverter Circuit and 1 Blink SOS ...
Page 35: ...Slide 35 LED Backlight Control ...
Page 47: ...Slide 47 SOS Detect Shutdown ...
Page 50: ...Slide 50 TC L32U22_1 Blink SOS Circuit ...
Page 53: ...Slide 53 3 and 7 Blinks SOS Circuit ...
Page 80: ...Slide 80 Troubleshooting Picture problem D Series Troubleshooting Picture problem D Series ...