PIPE INSULATION
6
1. Please carry out insulation at pipe connection portion as mentioned
in Indoor/Outdoor Unit Installation Diagram. Please wrap the
insulated piping end to prevent water from going inside the piping.
2. If drain hose or connecting piping is in the room (where dew may
form), please increase the insulation by using POLY-E FOAM with
thickness 6 mm or above.
•
Select required direction and apply protective bushing
provided in accessories to protect cables from sharp edges.
•
Once all wiring work has been completed, tie the cable and
cord together with the binding strap so that they do not touch
other parts such as the compressor and bare copper pipes.
Outdoor Unit
Banding strap
(Field Supply)
Cord clamp
Indoor/outdoor unit
terminal board
Connecting cable
(refer below
diagram for its
guiding)
Selection
of direction
Protective
bushing
3
Apply cut
DETAIL OF CONNECTING CABLE GUIDING
5 mm or more
(gap between wires)
Indoor/outdoor
connecting terminal
board
Wire stripping
No loose strand when insert
10 ± 1 mm
ACCEPT
Conductor over
insert
Conductor not
fully insert
Conductor fully
insert
PROHIBITED
PROHIBITED
WIRE STRIPPING AND CONNECTING REQUIREMENT
Models
Flexible cable specifi cation
UX09*E5*, UX12*E5*,
UD12*E5*, UD16*E5*
4 x min 4.0 mm
2
or 6.0 mm²
Terminals on the indoor unit
1
2
3
Colour of wires
Terminals on the outdoor unit
1
2
3
Earth Wire
must be
longer than
others cables
for safety
reason.
Models
Flexible cable specifi cation
UX09*E8*, UX12*E8*,
UX16*E8*, UD09*E8*,
UD12*E8*, UD16*E8*
6 x min 1.5 mm
2
Terminals on the indoor unit
1
2
3
4
5
Colour of wires
Terminals on the outdoor unit
1
2
3
4
5
Earth Wire
must be
longer than
others cables
for safety
reason.
CAUTION
•
For three phase model never operate the unit by pressing the
electromagnetic switch.
•
Never correct the phase by switching over any of the wires inside
the unit.