![Panasonic UJ20 Series How To Use Manual Download Page 3](http://html1.mh-extra.com/html/panasonic/uj20-series/uj20-series_how-to-use-manual_3730191003.webp)
Matsushita Electric Works, Ltd.
Global Marketing Division
3
Emergency stop of UV irradiation -2: STOP signal
Use the [STOP] signal terminal [9] to stop the UV irradiation of UJ20.
When the signal is input between terminals [9] and [12], the UV
irradiation will stop, and the [ERROR] signal will be turned on.
[ERROR] is output because the UV irradiation has not completed.
Input [STOP] again or hold down the [SET] key to release
the [ERROR] signal.
COM
ERROR
START
STOP
T
START
UV
STOP
ERROR
Equipment
design