background image

Operating Instructions 

Air Conditioner

Model No.

OUTDOOR UNIT

Single Split 

(Single-phase)

Type PZH3

U-71PZH3R5

U-100PZH3R5

U-125PZH3R5

U-140PZH3R5

Single Split 

(3-phase)

Type PZH3

U-100PZH3R8

U-125PZH3R8

U-140PZH3R8

● 

Connectable indoor unit lineup

This booklet is the operating instructions for outdoor unit. Regarding the indoor unit, see the 

operating instructions supplied with the indoor unit.

INDOOR UNIT

4-Way Cassette

Wall-Mounted

Ceiling

Middle Static Pressure Duct

Ducted

Panasonic Corporation

1006 Kadoma, Kadoma City, Osaka, Japan

ACXF55-29730

Before operating the unit, read these operating instructions thoroughly and keep them for future reference.

Type 71

Type 100, 125, 140

https://eu.datanavi.ac.smartcloud.panasonic.com/documents/

OI_00_321311_en.indb   1

2020/9/16   13:43:09

Summary of Contents for U-100PZH3R5

Page 1: ...for outdoor unit Regarding the indoor unit see the operating instructions supplied with the indoor unit INDOOR UNIT 4 Way Cassette Wall Mounted Ceiling Middle Static Pressure Duct Ducted Panasonic Corporation 1006 Kadoma Kadoma City Osaka Japan ACXF55 29730 Before operating the unit read these operating instructions thoroughly and keep them for future reference Type 71 Type 100 125 140 https eu da...

Page 2: ...e product damage burst and injury etc This air conditioner has no ventilator for intaking fresh air from outdoors You must open doors or windows frequently when you use gas or oil heating appliances in the same room which consume a lot of oxygen from the air Otherwise there is a risk of suffocation in an extreme case Never use or store gasoline or other flammable vapor or liquid near the air condi...

Page 3: ...les must be incorporated in the fixed wiring in accordance with the wiring rules To prevent possible hazards from insulation failure the unit must be grounded The appliance shall be stored in a room without continuously operating ignition sources for example open flames an operating gas appliance or an operating electric heater Be aware that refrigerants may not contain an odour An unventilated ar...

Page 4: ...s or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Keep the fire alarm and the air outlet at least 1 5m away from the unit Do not cool or heat the room too much if babies or invalids are present Do not tu...

Page 5: ...s z z Each unit must be properly grounded with a ground or earth wire or through the supply wiring z z Wiring must be done by a qualified electrician Operation Preparation Turn the power mains on 5 hours before the start of operation For warm up z z Leave the power mains ON for continuous use ON NOTE Pull off the power plug from a receptacle or switch off the breaker or switch off the power discon...

Page 6: ...it Troubleshooting Refer to the Operating Instructions attached to the indoor unit Air intake Air intake Air outlet Air outlet Type 71 Type 100 125 140 A Model No CZ RTC4 For all indoor units Read the Operating Instructions included with the Remote Controller Wireless Remote Controller Timer Remote Controller Wired Remote Controller High spec Wired Remote Controller Optional Model No CZ RWS3 Infra...

Page 7: ...99 99 Model Name U 100PZH3R8 U 125PZH3R8 U 140PZH3R8 Power source 400 415 V 3N 50 Hz Cooling capacity kW 10 0 12 5 14 0 BTU h 34 100 42 700 47 800 Heating capacity kW 11 2 14 0 16 0 BTU h 38 200 47 800 54 600 Sound pressure level Cooling Heating dB A 52 52 53 53 54 54 Sound power level Cooling Heating dB A 68 68 69 69 70 70 Unit dimensions H W D mm 1 416 940 340 1 416 940 340 1 416 940 340 Net wei...

Page 8: ... 416 940 340 1 416 940 340 1 416 940 340 Net weight kg 66 99 99 99 Model Name U 100PZH3R8 U 125PZH3R8 U 140PZH3R8 Power source 400 415 V 3N 50 Hz Cooling capacity kW 9 5 12 1 13 4 BTU h 32 400 41 300 45 700 Heating capacity kW 10 8 13 5 15 5 BTU h 36 800 46 100 52 900 Sound pressure level Cooling Heating dB A 52 52 53 53 54 54 Sound power level Cooling Heating dB A 68 68 69 69 70 70 Unit dimension...

Reviews: