z
If the wires used are long, recalculate the load by adding the weights of
the wires.
z
Check with the builder (e.g. the construction JV) as to the strength of
the section where the PDP is hung (e.g. steel frames, ceiling slab) to
confirm that the section has adequate strength before starting the work.
If the strength is not adequate, it is fully expected that the section
cannot withstand the load only with external anchors.
z
Ensure that the wires have been processed with specified parts and
tools and maintain the specified strength.
z
The breaking strength of stainless steel wires varies depending on the
manufacturer. Therefore, when using a stainless steel wire, check with
the specifications of the wire to confirm that it has the required strength.