1 Safety Precautions
1.1.
General Guidelines
1. When conducting repairs and servicing, do not attempt to modify the equipment, its parts or its materials.
2. When wiring units (with cables, flexible cables or lead wires) are supplied as repair parts and only one wire or some of the
wires have been broken or disconnected, do not attempt to repair or re-wire the units. Replace the entire wiring unit instead.
3. When conducting repairs and servicing, do not twist the Faston connectors but plug them straight in or unplug them straight
out.
4. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
5. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly
installed.
6. After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards.
1.1.1.
Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the
two prongs on the plug.
2. Measure the resistance value, with an ohmmeter,
between the jumpered AC plug and each exposed metal-
lic cabinet part on the equipment such as screwheads,
connectors, control shafts, etc. When the exposed metal-
lic part has a return path to the chassis, the reading
should be between 1Mohm and 5.2Mohm.
When the exposed metal does not have a return path to
the chassis, the reading must be
.
Figure 1
1.1.2.
Leakage Current Hot Check (See
Figure 1.)
1. Plug the AC cord directly into the AC outlet. Do not use
an isolation transformer for this check.
2. Connect a 1.5kohm, 10 watts resistor, in parallel with a
0.15
µ
F capacitors, between each exposed metallic part
on the set and a good earth ground such as a water pipe,
as shown in Figure 1.
3. Use an AC voltmeter, with 1000 ohms/volt or more sensi-
tivity, to measure the potential across the resistor.
4. Check each exposed metallic part, and measure the volt-
age at each point.
5. Reverse the AC plug in the AC outlet and repeat each of
the above measurements.
6. The potential at any point should not exceed 0.75 volts
RMS. A leakage current tester (Simpson Model 229 or
equivalent) may be used to make the hot checks, leakage
current must not exceed 1/2 milliamp. In case a measure-
ment is outside of the limits specified, there is a possibility
of a shock hazard, and the equipment should be repaired
and rechecked before it is returned to the customer.
Summary of Contents for TH-85PF12U
Page 6: ...6 TH 85PF12U 3 Service Navigation 3 1 Service Hint ...
Page 8: ...8 TH 85PF12U 3 2 Applicable signals ...
Page 9: ...9 TH 85PF12U ...
Page 11: ...11 TH 85PF12U 5 Operating Instructions ...
Page 16: ...16 TH 85PF12U 6 2 IIC mode structure following items value is sample data ...
Page 49: ...49 TH 85PF12U 10 1 9 Adjustment Volume Location 10 1 10 Test Point Location ...
Page 51: ...51 TH 85PF12U ...
Page 53: ...53 TH 85PF12U ...
Page 54: ...54 TH 85PF12U ...
Page 55: ...TH 85PF12U 55 11 Block Diagram 11 1 Diagram Notes ...
Page 66: ...TH 85PF12U 66 ...
Page 67: ...67 TH 85PF12U 12 Wiring Connection Diagram 12 1 Wiring 1 ...
Page 68: ...68 TH 85PF12U 12 2 Wiring 2 ...
Page 69: ...69 TH 85PF12U 12 3 Wiring 3 ...
Page 70: ...Model No TH 85PF12U Exploded View ...
Page 71: ...Model No TH 85PF12U Side Power part location ...
Page 72: ...Model No TH 85PF12U Cabinet part location ...
Page 73: ...Model No TH 85PF12U Fan part location ...
Page 74: ...Model No TH 85PF12U Rear cover location ...
Page 75: ...Model No TH 85PF12U Print Circuit Board ...
Page 76: ...Model No TH 85PF12U Flat cable ...
Page 77: ...Model No TH 85PF12U Packing and Accessories 1 ...
Page 78: ...Model No TH 85PF12U Packing 2 ...
Page 79: ...Model No TH 85PF12U Packing 3 ...