40
PJLink™ Protocol
The network function of the unit conforms with PJLink™ class 1 and you can operate the following actions from your
computer using PJLink™ protocol.
• Display setup
• Display status query
Supported commands
Commands to control the unit with PJLink™ protocol are shown in the table below.
PJLink™ security authentication
When using PJLink with security authorization, either of the password set for administrator privileges and the
password set for user privileges with Web browser control can be used as the password for PJLink (See page 28).
When using PJLink without security authorization, set use without the password for administrator privileges and the
password for user privileges of Web browser control.
• PJLink™ is a pending trademark in Japan, the United States, and other countries and regions.
Concerning the specification of PJLink™, see the website of Japan Business Machine and Information System
Industries Association (JBMIA) below:
http://pjlink.jbmia.or.jp/english/index.html
Command
Control
Remark
POWR
Power control
Parameter
0 = Standby 1 = Power “On”
POWR?
Power status query
Parameter
0 = Standby 1 = Power “On”
INPT
Input switch
Parameter
See the parameter for command INST?
INPT?
Input switch query
AVMT
Shutter control
Parameter
10 = Picture On (picture mute deactivated), 11 = Picture Off (picture on mute)
20 = Audio On (audio mute deactivated), 21 = Audio Off (audio on mute)
30 = Shutter mode Off (picture and audio mute deactivated)
31 = Shutter mode On (picture and audio on mute)
AVMT?
Shutter control query
Parameter
11 = Picture Off (picture on mute)
21 = Audio Off (audio on mute)
30 = Shutter mode Off (picture and audio mute deactivated)
31 = Shutter mode On (picture and audio on mute)
ERST?
Error status query
Parameter
First byte: Means fan error. 0 or 2.
Second byte: 0
Third byte: 0
Fourth byte: 0
Fifth byte: 0
Sixth byte: Means other error. 0 or 2.
Meaning of the 0 – 2 settings:
0 = Error is not detected, 2 = Error
LAMP?
Lamp status query
Not supported
INST?
Input switch list query
■
INST ?Command
%1INST=11 12 13 21 22 31 32 33 34 35 51 52 53
11: PC
12: SLOT INPUT or SLOT INPUT A
13: SLOT INPUT B
21: VIDEO
31: HDMI1
33: DVI-D
35: WHITEBOARD
52: Panasonic APPLICATION
22: COMPONENT
32: HDMI2
34: DIGITAL LINK
51: MIRRORING
53: MEMORY VIEWER
NAME?
Display name query
The name set for “Name change” in “Network settings” is returned.
INF1?
Manufacturer name query Returns “Panasonic”
INF2?
Model name query
Returns “80BF1U” / “65BF1U” / “50BF1U” (U model)
Returns “80BF1E” / “65BF1E” / “50BF1E” (E model)
Returns “80BF1W” / “65BF1W” / “50BF1W” (W model)
INFO?
Other information query
Returns version number
CLSS?
Class information query
Returns “1”