6. Do not remove a replacement ES device from its protective
package until immediately before you are ready to install it. (Most
replacement ES devices are packaged with leads electrically
shorted together by conductive foam, aluminum foil or comparable
conductive material).
7. Immediately before removing the protective material from the
leads of a replacement ES device, touch the protective material to
the chassis or circuit assembly into which the device will be
installed.
Caution
Be sure no power is applied to the chassis or circuit, and observe
all other safety precautions.
8. Minimize bodily motions when handling unpackaged replacement
ES devices. (Otherwise hamless motion such as the brushing
together of your clothes fabric or the lifting of your foot from a
carpeted floor can generate static electricity (ESD) sufficient
todamage an ES device).
4. About lead free solder (PbF)
Note: Lead is listed as (Pb) in the periodic table of elements.
In the information below, Pb will refer to Lead solder, and PbF will refer to Lead Free Solder.
The Lead Free Solder used in our manufacturing process and discussed below is (Sn+Ag+Cu).
That is Tin (Sn), Silver (Ag) and Copper (Cu) although other types are available.
This model uses Pb Free solder in it’s manufacture due to environmental conservation issues.
For service and repair work, we’d suggest the use of Pb free solder as well, although Pb solder
may be used.
PCBs manufactured using lead free solder will have the PbF within a leaf Symbol
stamped on the back of PCB.
Caution
- Pb free solder has a higher melting point than standard solder.
Typically the melting point is 50 ~ 70 °F (30~40 °C) higher. Please
use a high temperature soldering iron and set it to 700 ± 20 °F (370
6
Summary of Contents for TH-65PHD8BK
Page 3: ...1 Applicable signals 2 Safety Precautions 3 ...
Page 34: ...34 ...
Page 38: ...9 5 Test Point Location 10 Service mode 10 1 CAT computer Aided Test mode 38 ...
Page 45: ...13 Option Setting 45 ...
Page 53: ...16 1 2 Escutcheon part location enlarged view 53 ...
Page 54: ...16 1 3 Fan part location enlarged view 16 2 Cable relation 54 ...
Page 55: ...16 3 Packing summary 55 ...
Page 56: ...56 ...
Page 60: ...18 2 Electrical Replacement Parts List 60 ...
Page 62: ...C466 69 ECJ2FB1H104K C 0 1UF K 50V 4 62 ...
Page 64: ...C831 EEEHB1C470P C 47PF J 16V 1 64 ...
Page 79: ...D3061 MA728 DIODE 1 79 ...
Page 90: ...Q6223 B1DFKL000001 TRANSISTOR 1 90 ...
Page 121: ...SD46 K1KA10B00209 10P CONNECTOR 1 121 ...
Page 173: ...15 1 Schematic Diagram Notes 15 Schematic Diagrams TH 65PHD8BK TH 65PHD8EK TH 65PHD8UK 69 ...
Page 174: ...15 1 Schematic Diagram Notes 15 Schematic Diagrams TH 65PHD8BK TH 65PHD8EK TH 65PHD8UK 69 ...