2 Safety Precautions
2.1. General Guidelines
1. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
2. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly
installed.
3. After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards.
2.2. Touch-Current Check
1. Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this check.
2. Connect a measuring network for touch currents between each exposed metallic part on the set and a good earth ground such
as a water pipe, as shown in Figure 1.
3. Use Leakage Current Tester (Simpson 228 or equivalent) to measure the potential across the measuring network.
4. Check each exposed metallic part, and measure the voltage at each point.
5. Reserve the AC plug in the AC outlet and repeat each of the above measure.
6. The potential at any point (TOUGH CURRENT) expressed as voltage U
1
and U
2
, does not exceed the following values:
For a. c.: U
1
= 35 V (peak) and U
2
= 0.35 V (peak);
For d. c.: U
1
= 1.0 V,
Note:
The limit value of U
2
= 0.35 V (peak) for a. c. and U
1
= 1.0 V for d. c. correspond to the values 0.7 mA (peak) a. c. and 2.0
mA d. c.
The limit value U
1
= 35 V (peak) for a. c. correspond to the value 70 mA (peak) a. c. for frequencies greater than 100 kHz.
7. In case a measurement is out of the limits specified, there is a possibility of a shock hazard, and the equipment should be
repaired and rechecked before it is returned to the customer.
Figure 1
5
TH-65PF9BK / TH-65PF9EK
Summary of Contents for TH-65PF9BK
Page 4: ...1 Applicable signals 4 TH 65PF9BK TH 65PF9EK ...
Page 23: ...7 Location of Lead Wiring 23 TH 65PF9BK TH 65PF9EK ...
Page 24: ...24 TH 65PF9BK TH 65PF9EK ...
Page 27: ...8 4 Adjustment Volume Location 8 5 Test Point Location 27 TH 65PF9BK TH 65PF9EK ...
Page 32: ...9 2 IIC mode structure following items value is sample data 32 TH 65PF9BK TH 65PF9EK ...
Page 34: ...34 TH 65PF9BK TH 65PF9EK ...
Page 36: ...36 TH 65PF9BK TH 65PF9EK ...
Page 42: ...12 Option Setting 42 TH 65PF9BK TH 65PF9EK ...
Page 44: ...NOTE 44 TH 65PF9BK TH 65PF9EK ...
Page 78: ...NOTE TH 65PF9BK TH 65PF9EK 78 ...
Page 79: ...14 1 Schematic Diagram Notes 14 Block and Schematic Diagram TH 65PF9BK TH 65PF9EK 79 ...
Page 148: ...NOTE TH 65PF9BK TH 65PF9EK 148 ...
Page 151: ...15 2 Cable relation 151 TH 65PF9BK TH 65PF9EK ...
Page 152: ...15 3 Packing summary 152 TH 65PF9BK TH 65PF9EK ...
Page 153: ...153 TH 65PF9BK TH 65PF9EK ...
Page 154: ...154 TH 65PF9BK TH 65PF9EK ...
Page 156: ...17 Replacement Parts List 17 1 Replacement Parts List Notes 156 TH 65PF9BK TH 65PF9EK ...