9.2. Initialization Pulse Adjust
1. Input a white signal to plasma video input.
2. Set the picture adjustment items as follows.
·
Picture menu : Standard
·
Color temperature : Normal
·
Picture : 25
·
Aspect : Full
3. Connect Oscilloscope to TPSC1 (T1) and check for 20 ± 15µ Sec.
4. Connect Oscilloscope to TPSC1 (T2) and adjust VR6602 for 155 ± 10µ Sec.
Test point
Volume
Level
T1
TPSC1 (SC)
Fixed
20 ± 15µ Sec
T2
TPSS1 (SS)
VR6602(SC)
155 ± 10µ Sec
9.3. P.C.B. (Printed Circuit Board) Remove
9.3.1. Caution
1. To remove P.C.B. , wait 1 minute after power was off for discharge from electrolysis capacitors.
9.3.2. Quick adjustment after P.C.B. Remove
P.C.B.
Name
Test Point
Voltage
Volume
Remarks
P Board
Vsus
TPVSUS
176V ± 2V
VR351 (P)
*
SC Board
Vad
TPVAD
-90V ± 1V
VR6801 (SC)
Vscn
TPVSCN
Vad+ 130V ± 4V
Fixed
Vset
TPVSET
225V ± 7V
Fixed
SS Board
Ve
TPVE
150V ± 1V
VR6250 (SS)
*
Vda
TPVDA
75V ± 1V
Fixed
D, J Board
White balance, Pedestal and Sub brightness for NTSC, PAL, HD, PC and 625i signals
*See the Panel label.
Caution:
Absolutely do not reduce Vsus below Ve not to damage the P.C.B.
24
TH-50PHD8BK / TH-50PHD8BS / TH-50PHD8EK / TH-50PHD8ES
Summary of Contents for TH-50PHD8BK
Page 4: ...1 Applicable signals 4 TH 50PHD8BK TH 50PHD8BS TH 50PHD8EK TH 50PHD8ES ...
Page 21: ...8 Location of Lead Wiring 21 TH 50PHD8BK TH 50PHD8BS TH 50PHD8EK TH 50PHD8ES ...
Page 22: ...22 TH 50PHD8BK TH 50PHD8BS TH 50PHD8EK TH 50PHD8ES ...
Page 36: ...13 Option Setting 36 TH 50PHD8BK TH 50PHD8BS TH 50PHD8EK TH 50PHD8ES ...
Page 38: ...38 TH 50PHD8BK TH 50PHD8BS TH 50PHD8EK TH 50PHD8ES ...
Page 120: ...TH 50PHD8BK TH 50PHD8BS TH 50PHD8EK TH 50PHD8ES 120 ...
Page 123: ...16 2 Cable relation 123 TH 50PHD8BK TH 50PHD8BS TH 50PHD8EK TH 50PHD8ES ...
Page 124: ...16 3 Packing summary 124 TH 50PHD8BK TH 50PHD8BS TH 50PHD8EK TH 50PHD8ES ...
Page 125: ...125 TH 50PHD8BK TH 50PHD8BS TH 50PHD8EK TH 50PHD8ES ...