11 Alignment
11.1. PC/RGB panel white balance
1 PC
Color
Picture:
Gray Scale
Analyzer
Normal
Pattern
White balance:
Cool
Aspect:
16:9
1) Set G cut off to " 80 ".
High light 75%
Low light 15%
2)Find 75% of white area by color sensor.
PANEL W/B
G Drive 3) Set G Drive to " E8 ".
PANEL W/B
B Drive 4) Adjust B and R Drive to set color temperature
R Drive as shown Fig.-03.
PANEL W/B
R,G,B Drive 5) Increase same steps of R, G and B Drive to set
R,G,B Drive largest level of 3 color drive to "FC".
PANEL W/B
R,G,B cut off
Color Temp.
x
y
Cool(Hi)
0.276
0.276
Normal(Mid)
0.288
0.296
Warm(Low)
0.313
0.329
Fig. -03
2
Picture:
1) Change white balance to "Normal".
Normal PANEL W/B
White balance:
R,G,B cut off 2) Repeat procedure 1) to 5) of Cool mode.
Normal
PANEL W/B
Aspect:
R,G,B Drive
16:9
3
Picture:
1) Change white balance to "Warm".
Normal PANEL W/B
White balance:
R,G,B cut off 2) Repeat procedure 1) to 5) of Cool mode.
Warm
PANEL W/B
Aspect:
R,G,B Drive
16:9
4
Picture:
Picture Menu
1) Change color templature to "Cool".
Normal Sub Adjust
White balance:
Sub Bright
Cool
Aspect:
16:9
INPUT
Alignment menu
Procedure
Equipment
Setting
23
TH-50PHW7BX / TH-50PHW7EX / TH-50PHD7EK / TH-50PHD7ES / TH-50PHD7BK / TH-50PHD7BS / TH-50PHD7UY