8.3.
P.C.B. (Printed Circuit Board) exchange
8.3.1.
Caution
1. To remove P.C.B. , wait 1 minute after power was off for discharge from electrolysis capacitors.
8.3.2.
Quick adjustment after P.C.B. exchange
P.C.B.
Name
Test Point
Voltage
Volume
Remarks
P Board
Vsus
TPVSUS (SS)
170V ± 2V
R641 (P)
Vda
TPVDA (SS)
67V ± 1V
R665 (P)
SC Board
Vad
TPVAD (SC)
-90V ± 1V
R6477 (SC)
Vset
TPVSET (SC)
220V ± 5V
---
Vscn
TPVSCN (SC)
Vad + 118 ± 2V
---
SS Board
Ve
TPVE (SS)
158V ± 1V
R6770 (SS)
D, J Board
White blance, Pedestal and Sub brightness for NTSC, PAL, HD, PC and 625i signals
*See the Panel label.
8.4.
Adjustment Volume Location
8.5.
Test Point Location