12 Adjustment
12.1. White balance adjustment
Name of measuring instrument
Connection
Remarks
·
W/B pattern
·
Color analyzer
(Minolta CA-100 or equivalent)
Component input
Panel surface
Procedure
Remarks
·
Ensure aging is adequate.
·
Make sure the front panel to be used on the final set is fitted.
·
Make sure a color signal is not being shown before adjustment.
·
Put the color analyzer where there is little color variation.
1.
Output a white balance pattern.
2.
Check that the color temperature is “Cool”.
3.
Set to serviceman mode, WB-ADJ.
4. Set “R-CUT” “G-CUT” “B-CUT” the values written in table 1.
5.
Attach the sensor of color analyzer to he center of highlight window.
6.
Fix G drive at C0h and adjust “B-DRV” and “R-DRV” so x, y value of color analyzer
become the “Color temperature High” in table 2.
7.
Increase RGB together so the maximum drive value in RGB becomes FCh. That is,
set “ALL DRIVE” to FCh.
8. Set color temperature to “Normal”.
9.
Set “R-CUT” “G-CUT” “B-CUT” the values written in table 1.
10. Attach the sensor of color analyzer to the center of highlight window.
11. Fix G drive at C0h and adjust “B-DRV” and “R-DRV” so x, y value of color analyzer
become the “Color temperature Mid” in table 2.
12. Increase RGB together so the maximum drive value in RGB becomes FCh. That is,
set “ALL DRIVE” to FCh.
13. Set color temperature to “Warm”.
14. Set “R-CUT” “G-CUT” “B-CUT” the values written in table 1.
15. Attach the sensor of color analyzer to the center of highlight window.
16. Fix G drive at C0h and adjust “B-DRV” and “R-DRV” so x, y value of color analyzer
become the “Color temperature Low” in table 2.
17. Increase RGB together so the maximum drive value in RGB becomes FCh. That is,
set “ALL DRIVE” to FCh.
18. Set color temperature to “Cool”.
[ adjustment of “Normal” “Warm” by data shift from “Cool” adjust. ]
For “Normal” “Warm” adjustment, set values that the adjusted value of “Cool”
plus the figures wrote below.
19. Copy values adjusted by HD pattern to the NTSC data area of EEPROM.
31
TH-42PE7U
Summary of Contents for TH-42PE7U
Page 4: ...1 Applicable signals 4 TH 42PE7U ...
Page 15: ...8 Location of Lead Wiring 8 1 Lead of Wiring 1 15 TH 42PE7U ...
Page 16: ...8 2 Lead of Wiring 2 16 TH 42PE7U ...
Page 17: ...8 3 Lead of Wiring 3 17 TH 42PE7U ...
Page 18: ...8 4 Lead of Wiring 4 18 TH 42PE7U ...
Page 19: ...8 5 Lead of Wiring 5 19 TH 42PE7U ...
Page 23: ...9 4 No Picture 23 TH 42PE7U ...
Page 30: ...11 4 Adjustment Volume Location 11 5 Test Point Location 30 TH 42PE7U ...
Page 32: ...32 TH 42PE7U ...
Page 34: ...34 TH 42PE7U ...
Page 53: ...15 1 Schematic Diagram Note 15 Schematic and Block Diagram TH 42PE7U 53 ...
Page 102: ...TH 42PE7U 102 ...
Page 103: ...16 Exploded Views Replacement Parts List 16 1 Exploded Views 103 TH 42PE7U ...
Page 104: ...16 2 Packing Exploded Views Accessories box 104 TH 42PE7U ...
Page 105: ...16 3 Packing Exploded Views Stand 105 TH 42PE7U ...
Page 106: ...16 4 Replacement Parts List Notes 106 TH 42PE7U ...