6. Remove the spacers and spacer rings (×6
).
6.18. Replace the plasma panel
(finished)
1. Place the new plasma panel (finished) on the flat surface of
the table (covered by a soft cloth), with the plasma panel
surface facing downward.
2. Attach the C1-Board and the C2-Board, connect the flexible
cables (×16) from the Plasma panel to the C1-Board and
the C2-Board, and fit the flexible cable holders.
3. Attach the Hooks (left, right) and fit the stand brackets (L,
R) to the new plasma panel.
4. Place the plasma panel section on the servicing stand.
5. Attach the cabinet assy and each P.C.Board and so on, to
the new plasma panel.
*When fitting the front frame, be careful not to allow any
debris, dust or handling residue to remain between the
front glass and plasma panel.
13
TH-42PE7U
Summary of Contents for TH-42PE7U
Page 4: ...1 Applicable signals 4 TH 42PE7U ...
Page 15: ...8 Location of Lead Wiring 8 1 Lead of Wiring 1 15 TH 42PE7U ...
Page 16: ...8 2 Lead of Wiring 2 16 TH 42PE7U ...
Page 17: ...8 3 Lead of Wiring 3 17 TH 42PE7U ...
Page 18: ...8 4 Lead of Wiring 4 18 TH 42PE7U ...
Page 19: ...8 5 Lead of Wiring 5 19 TH 42PE7U ...
Page 23: ...9 4 No Picture 23 TH 42PE7U ...
Page 30: ...11 4 Adjustment Volume Location 11 5 Test Point Location 30 TH 42PE7U ...
Page 32: ...32 TH 42PE7U ...
Page 34: ...34 TH 42PE7U ...
Page 53: ...15 1 Schematic Diagram Note 15 Schematic and Block Diagram TH 42PE7U 53 ...
Page 102: ...TH 42PE7U 102 ...
Page 103: ...16 Exploded Views Replacement Parts List 16 1 Exploded Views 103 TH 42PE7U ...
Page 104: ...16 2 Packing Exploded Views Accessories box 104 TH 42PE7U ...
Page 105: ...16 3 Packing Exploded Views Stand 105 TH 42PE7U ...
Page 106: ...16 4 Replacement Parts List Notes 106 TH 42PE7U ...