10.3. Initialization Pulse Adjust
1. Input a Cross hatch signal.
2. Set the picture controls: -
Picture mode: Normal
White balance: Cool
Adjust the indicated test point for the specified wave form.
Test point
Volume
Level
T1
TPSC1 (SC)
R6523 (SC)
20 ± 15µ Sec
T2
TPSS1 (SS)
R6557 (SC)
170 ± 20µ Sec
23