10
TH-37PR11UK / TH-37PR11UH
GPH11D chassis series have special function and operation setting facility called Option Menu. This Option Menu is use-
ful for special function required customers. This should be set at the installation stage.
Note:
When both main unit buttons and remote control are disabled due to the “Button lock”, “Remocon User level” or “Remote ID”
adjustments, set all the values “Off” so that all the buttons are enabled again.
Press the “Volume down” button on main unit together with “R” button on the remote control and hold for more than 5 seconds.
The “SHIPPING“ menu is displayed and the lock is released when it disappears.
Option Menu for GPH11D series
Option menus
default setting
Contents
Weekly Command Timer
---
Sets Weekly Command Timer.
Onscreen display
On
Enable/Disable to display input mode indication after power on and no signal
indication.
Initial INPUT
Off
Sets the initial input mode when the power is turned on. Allow input mode selec-
tion while power is on.
Initial VOL level
Off
Sets the initial volume level when the power is turned on. Allow Volume control
while power is on.
Maximum VOL Level
Off
Sets the maximum volume to desired level. Volume cannot exceed this level.
INPUT lock
Off
Fixes the input mode to AV, Component/RGB or PC. Can not change input
mode by input selection key.
Button lock
Off
Enable/Disable bottom operation buttons (Input, Menu, Enter and/or volume up/
down)
Remocon User Level
Off
Remote key invalidation.
Off: Valid key is all key of remote.
User1: Valid key are only Stand-by (ON/OFF), Input, Direct input, Picture, Sur-
round, Sound mute On/Off, and volume adjustment.
User2: Valid key is only Stand-by (ON/OFF).
User3: All keys are null and void
Advanced PIP
Off
Off: Sets normal two screen display mode.
On: Sets Advanced PIP mode.
Off-timer function
Enable
Off-timer operation Enable/Disable.
Initial Power Mode
Normal
Sets the power mode of the unit for when the power recovers from failure or
after plugging off and in again.
ID select
0
Set ID number from 0 to 100.
Remote ID
Off
Remote ID function On/Off.
(While the Remote ID on, standard remote function can not control the unit.)
Serial ID
Off
Serial ID function On/Off
Slot power
Off
Sets the slot power mode while the power is turned on.
Allow Optional Terminal Board insert Slots while power is on.
Power On Screen Delay
Off
You can set the power-on delay time of the displays to reduce the power load,
when you press
to turn on the multiple displays that are set together, for
example, on MULTI DISPLAY system.
Set each display’s setting individually.
Clock Display
Off
Clock Display function On/Off.
All Aspect
Default
Aspect mode: default/All aspect mode.
Serial Slot Select
Slot1
Selects the slot which communicates serial.
Note:
The setting of an external command can be set only from the fixed serial
terminal.
Summary of Contents for TH-37PR11UK
Page 7: ...7 TH 37PR11UK TH 37PR11UH 3 2 Applicable signals ...
Page 9: ...9 TH 37PR11UK TH 37PR11UH 5 Operating Instructions ...
Page 14: ...14 TH 37PR11UK TH 37PR11UH 6 2 IIC mode structure following items value is sample data ...
Page 29: ...29 TH 37PR11UK TH 37PR11UH 9 1 4 Adjustment Volume Location 9 1 5 Test Point Location ...
Page 31: ...31 TH 37PR11UK TH 37PR11UH ...
Page 33: ...33 TH 37PR11UK TH 37PR11UH ...
Page 42: ...TH 37PR11UK TH 37PR11UH 42 NOTE ...
Page 43: ...43 TH 37PR11UK TH 37PR11UH 11 Wiring Connection Diagram 11 1 Wiring 1 ...
Page 44: ...44 TH 37PR11UK TH 37PR11UH 11 2 Wiring 2 ...
Page 45: ...45 TH 37PR11UK TH 37PR11UH 11 3 Wiring 3 ...
Page 46: ...46 TH 37PR11UK TH 37PR11UH 11 4 Wiring 4 ...
Page 47: ...TH 37PR11UK TH 37PR11UH 47 12 Schematic Diagram 12 1 Schematic Diagram Notes ...
Page 104: ...TH 37PR11UK TH 37PR11UH 104 NOTE ...
Page 139: ...Model No TH 37PR11UK UH Important Safety Notice ...
Page 140: ...Model No TH 37PR11UK UH Exploded View ...
Page 141: ...Model No TH 37PR11UK UH Cabinet part location ...
Page 142: ...Model No TH 37PR11UK UH Flat cable relation ...