5-3. How to adjust the waveform
<Procedure>
<Location of Test point and Volume>
VR6602
VR6601
TPSC1
(SC Board)
190 + -7V
80uS
(Fig 1)
(Fig 2)
1. Set Aging pattern 0 (Vset adjustment pattern) by IIC mode.
2. Set the picture adjustment items as follows.
(1) Picture menu : Standard
(2) Color temperature : Normal
(3) Picture : 25
(4) Aspect : Full
3. Connect Oscilloscope to “TPSC1” and confirm the
initialization pulse.
4. Voltage and waveform adjustments are as follows.
Confirmation Point
Start up of initialization pulse
T2 period
Volume
VR6601 (SC)
VR6602 (SC)
Level
190V (+ -7V)
165 (+ -10)uSec
Remarks
Fig 1
Fig 2
T2
Summary of Contents for TH-103PF9CK
Page 4: ...Preparation for exchange the panel Preparation for exchange the panel Step 1 Step 1 Step 1 ...
Page 10: ...Move the panel to the stand Move the panel to the stand Step 2 Step 2 Step 2 ...
Page 21: ...Replace the escutcheon Replace the escutcheon Step 3 Step 3 ...
Page 34: ...Replace the PCB Replace the PCB Step 4 Step 4 ...
Page 43: ...Note ...
Page 44: ......