5-2-1. How to adjust the voltage
<Procedure>
1. Set Aging pattern 0 (Vset adjustment pattern) by IIC mode.
2. Set the picture adjustment items as follows.
(1) Picture menu : Standard
(2) Color temperature : Normal
(3) Picture : 25
(4) Aspect : Full
3. Check and adjust the following voltages with digital multi meter.
Before adjusting the Vsus and Ve voltage, please refer to the
panel data on the panel label.
(Panel label)
Name
Test Point
Voltage
Volume
Vsus
TPVSUS (SC)
Vsus (+ - 0.5V)
VR251 (P_SC)
Vsus
TPVSUS (SS)
Vsus (+ - 0.5V)
VR251 (P_SS)
Ve
TPVE (SS)
Ve (+ - 1V)
VR6000 (SS)
Vad
TPVAD (SC2)
-85V (+ - 1V)
VR6600 (SC2)
Vscn
TPVSCN (SC2)
Vad + 140V (+ - 4V)
VR6605 (SC2)
Vset
TPVSET (SC2)
240V (+ - 1V)
VR6604 (SC2)
Vset2
TPVSET2 (SC)
Vad + 8V (+1V, -0V)
VR6603 (SC)
Vbk
TPVBK (SC2)
150V (+ - 1V)
VR6351 (SC2)
Vc
TPVC (DR1)
45V (+ - 0.5V)
VR600 (DR1_SC)
Vc
TPVC (DR2)
45V (+ - 0.5V)
VR650 (DR2_SC)
Vc
TPVC (DR1)
34.5V (+ - 0.5V)
VR600 (DR1_SS)
Vc
TPVC (DR2)
34.5V (+ - 0.5V)
VR650 (DR2_SS)
Remarks
Refer to the number of VSUS on panel label
Refer to the number of VSUS on panel label
Refer to the number of Ve on panel label
Confirm the inserted DR6 connector
Confirm the inserted DR6 connector
Summary of Contents for TH-103PF9CK
Page 4: ...Preparation for exchange the panel Preparation for exchange the panel Step 1 Step 1 Step 1 ...
Page 10: ...Move the panel to the stand Move the panel to the stand Step 2 Step 2 Step 2 ...
Page 21: ...Replace the escutcheon Replace the escutcheon Step 3 Step 3 ...
Page 34: ...Replace the PCB Replace the PCB Step 4 Step 4 ...
Page 43: ...Note ...
Page 44: ......