- 8 -
TC-14B10P / TC-20B10P
Service Adjustments and Calibrations
2.7-
Apply a PHILIPS pattern.
2.8-
Adjust BRIGHT, SUB BR, in CHQ5, SCREEN to
obtain normal image.
2.9-
Check if horizontal width is normal
2.10- Select SUB BR in CHQ5 and check if BRIGHT is
controlled by varying SUB BR in CHQ5.
2.11- Select HORIZONTAL CENTERING (HC) in CHQ3
(Service Mode) and adjust convergence.
2.12- Select VERTICAL CENTERING (VC) in CHQ3
(Service Mode) and adjust convergence.
3-
PRÉ AJUSTE DO AGC RF.
3.1- Apply a PHILIPS pattern.
3.2- Adjust the signal level to 65±2bB (75
Ω
open).
3.3- Select
RF AGC
in
CHQ4
Service Mode and increase
it pressing
VOL(+)
. Verify if snow appear when the
RF AGC register is increased. Then decrease it slowly
by using
VOL(_)
until the snow has disappeared.
CUT OFF - PRE ADJUSTMENTS
1-
REQUIRED EQUIPMENTS.
1.1- Oscilloscope.
1.2- Connect oscilloscope between TPY1 (Q352-C) and
ground.
1.3- Position controls/adjust following the information
below:
R HIGH LIGHT (R-DR).................. 40H
B HIGH LIGHT (B-DR)...................40H
R LOW LIGHT (R-CUT).................000H
B LOW LIGHT (B-CUT)................. 000H
G LOW LIGHT (G-CUT)................ 125H
COR...............................................MINIMUM
CONTRASTE................................ MAXIMUM
SCREEN........................................MINIMUM
1.4- Apply a PHILIPS pattern.
1.5- Press 5 at the remote control to obtain a simple
horizontal line
1.6- Adjust G-CUT to obtain a reading at TPY1, as figure
below.(*)
1.7- Adjust SCREEN until a first line appears at the screen,
and dont change it after this.
1.8- Adjust the other DACs that match the other two
colours (R-CUT, B-CUT) until it turns the line white.
1.9- Exit to Normal Mode pressing NORMAL at the remote
control.
1-
SOUND INSPECTION
1.1- Verify if sound varies correctly pressing VOL(+) or
VOL(_).
1.2- Verify if tone is adjusted using the TONEcontrol at
the SOUND Menu.
2- INSPECTION OF COLOUR CONTROL
2.1- Apply a PHILIPS pattern.
2.2- Select Pic. Menu DYNAMIC, and adjust NORMAL
IMAGE using the remote control.
2.3- To access the function NORMAL IMAGE press MAIN
MENU and next press the
<
or
>
navigation keys to
select the function
IMAGE
.
Press the
navigation keys to enter menu. Press the
N
key at the remote control to activate function
NORMAL IMAGE.
2.4- Verify if saturation is normal and sufficcient.
2.5- Confirm the variation of the colour phase acting at the
TINT control, receiving NTSC pattern.
3-
OTHER INSPECTIONS.
3.1- Tune the VHF, UHF and CATV channels and check if
there is good reception.
3.2- Press the key
TV/VIDEO
and verify ON SCREEN.
3.3- Return to the TV Mode.
CALIBRATION OF VIDEO IF
1-
REQUIRED EQUIPMENT
1.1- Monitor
1.2- VIF generator
1.3- VIF detector
1.4- Power source of 9,0 ±0,1V and 4,0 ±0,1V
1.5- Bias box to AGC
1.6- Resistor Jumper of 1K
Ω
CONEXIONS
0V
(*) 20 inch 160 ± 2Vo-p
(*) 14 inch 140 ± 2Vo-p
<
Summary of Contents for TC-14B10P
Page 3: ... 3 Operation Guide TC 14B10P TC 20B10P ENGLISH ...
Page 4: ... 4 Operation Guide TC 14B10P TC 20B10P ...
Page 5: ... 5 Operation Guide TC 14B10P TC 20B10P ENGLISH ...
Page 15: ... 15 TC 14B10P TC 20B10P Schematics Diagrams Y Boad CRT 14 Y Boad CRT 20 Yoke Board ENGLISH ...
Page 19: ... 19 TC 14B10P TC 20B10P Cabinet Parts Location Vista por Explosión ENGLISH ESPAÑOL ...
Page 31: ... 31 Guia Rápido de Operación TC 14B10P TC 20B10P ESPAÑOL ...
Page 32: ... 32 Guia Rápido de Operación TC 14B10P TC 20B10P ...
Page 33: ... 33 Guia Rápido de Operación TC 14B10P TC 20B10P ESPAÑOL ...