- 6 -
TC-14B10P / TC-20B10P
Service Adjustments and Calibrations
HOW TO OPERATE THE DAC CONTROL MX5Y
FUNCTIONS ADJUSTMENTS
1- SERVICEMAN MODE
1.1- TO ENTER CHQ MODE (SERVICE):
Set the
OFF TIMER
to 30 using the remote control
and adjust minimum volume at the TV panel. Press
simultaneously
RECALL
at the remote control and
VOL(-)
at the tv panel. The white screen will appear
on receiver. Press
RECALL
again and the letters
CHQ
will appear magenta with a blue background.
1.2- To alternate between
CHQ
modes, press 1 or 2
at the remote control (CHQ1 to CHQ5)
1.3- TO EXIT CHQ MODE (SERVICE):
Press N at the remote control, or just turn off the TV
using the remote control.
CHQ1
1.1- Press3or 4 to alternate the existing options: from
OP1 to OP6.
1.2- To change the data inside each sub-item press
VOL(+) or VOL(_) (the letter will be red). To memorize
the modifications press 0 (the letter will come back
to green).
OP1 (Colour system)
This option alternates between colour systems that will be
available within the TV set.
OP1=0 auto/PAL-M/NTSC
(mod. Binorma)
OP2=1 auto/PAL-M/PAL-N/NTSC
(mod. Trinorma)
OP1=2 Pal-M
(mod.Pal-M)
OP2 (Game Function)
This option may turn the function
GAME
on/off.
OP3 (PANASONIC DEMO)
This option may turn the function
DEMO
on/off.
OP4 (TELE-TEXT) -
not available
This option may turn the function
TELE-TEXT
on/off.
OP5 (SASO) -
not available
This option may turn the function
SASO
on/off.
OP6 (NOISE MUTE) -
not available
This operation may turn the function
NOISE MUTE
on/off.
Without the blue screen, it cuts off the noise when you are
working on a channel without reception or very weak signal.
CHQ2
1.1- Press 3 or 4 to alternate between existing positions
like the sequence below:
To change between the data of each sub-item press
VOL(+) or VOL(_), the letter will stay green. No need
to memorize.
COLOUR ..........................USER
SUB-COLOUR
.................CALIBRATION
TINT ................................. USER
SUB-TINT
........................CALIBRATION
BRIGHT ........................... USER
SUB-BRIGHT
.................. CALIBRATION
CONTRAST ..................... USER
SUB-CONTRAST
............ CALIBRATION
PURITY ............................USER
SUB-PURITY
...................CALIBRATION
CHQ3
1.1- Press 3 or 4 to alternate between the existing
options, as sequence below:
To change between the data in each sub-item press
VOL(+) or VOL(_), the letter will stay green. No need
to memorize.
HC ....................... HORIZONTAL CENTERING
VC ....................... VERTICAL CENTERING
V ALT .................. VERTICAL HEIGHT
CHQ4
1.1- Press 3 or 4 to alternate between the existing
options, as sequence below:
To change between the data in each sub-item press
VOL(+) or VOL(_), the letter will stay green. No need
to memorize.
AFT ..................... AFT CALIBRATION
VID .............. .. VIDEO LEVEL CALIBRATION
RF ............ ..AGC-RF CALIBRATION
CHQ5
1.1- Press 3or 4 to alternate between the existing
options, as sequence below:
To change between the data in each sub-item press
VOL(+) or VOL(_), the letter will stay green. No need
to memorize.
CHQ5 Options:
B-CUT...........BLUE LOW LIGHT CALIBRATION
G-CUT.......... GREEN LOW LIGHT CALIBRATION
R-CUT...........RED LOW LIGHT CALIBRATION
B-DR. ........ BLUE HIGHT LIGHT CALIBRATION
R-DR ......... RED HIGH LIGHT CALIBRATION
SUB-BR........ SUB BRIGHT CALIBRATION
BRIGHT........ BRIGHT CALIBRATION
Summary of Contents for TC-14B10P
Page 3: ... 3 Operation Guide TC 14B10P TC 20B10P ENGLISH ...
Page 4: ... 4 Operation Guide TC 14B10P TC 20B10P ...
Page 5: ... 5 Operation Guide TC 14B10P TC 20B10P ENGLISH ...
Page 15: ... 15 TC 14B10P TC 20B10P Schematics Diagrams Y Boad CRT 14 Y Boad CRT 20 Yoke Board ENGLISH ...
Page 19: ... 19 TC 14B10P TC 20B10P Cabinet Parts Location Vista por Explosión ENGLISH ESPAÑOL ...
Page 31: ... 31 Guia Rápido de Operación TC 14B10P TC 20B10P ESPAÑOL ...
Page 32: ... 32 Guia Rápido de Operación TC 14B10P TC 20B10P ...
Page 33: ... 33 Guia Rápido de Operación TC 14B10P TC 20B10P ESPAÑOL ...