6
8) Error indicator (Red)
It lights up when an error occurs on the
S-LINK V
system main cable. In case the cause of the er-
ror is eliminated, it blinks, and if the error No. is cleared with program, or when the system setting
is done, it turns OFF.
Notes: 1) Error 0 to Error 6 cannot be distinguished with the error indicator. Check with a program on the
VME bus system by using “
5) HL00 + 004A to B, HL00 + 014A to B: Error No. / Error state
” in “
5.
Assignment on Program
.”
2) In case of turning OFF the blinking state, operate on the program.
Set the interruption level (IRQ1 to IRQ7) of VME bus.
In case an error occurs on the
S-LINK V
system main line or the input of the input unit is
changed, it processes at the interruption level that is set with the interruption level setting switch.
The above figure indicates the
interruption level “IRQ1.”
0
1
SW8
1
2
3
4
5
6
7
8
O
N
Level
1
2
3
4
5
6
7
8
Unused
OFF
OFF
OFF
OFF
IRQ1
ON
OFF
OFF
IRQ2
OFF
ON
OFF
IRQ3
ON
ON
OFF
IRQ4
OFF
OFF
ON
IRQ5
ON
OFF
ON
IRQ6
OFF
ON
ON
IRQ7
ON
ON
ON
Note: Settings other than the above diagram is invalid.
10) Status / ID setting switch (SW7)
Set the status / ID that is transferred when VME bus is interrupted, in binary digit.
bit 0: undermost, bit 7: uppermost, “ON” = 1, “OFF” = 0.
Note: Transfer capability of status / ID is D08 (O).
T h e a b o v e f i g u r e
shows “binary digit =
01100101,” and “hexa-
decimal = 65.”
SW7
1
2
3
4
5
6
7
8
O
N
0
1
bit
1
0
1
0 (2
0
)
ON
OFF
2
1 (2
1
)
3
2 (2
2
)
4
3 (2
3
)
5
4 (2
4
)
6
5 (2
5
)
7
6 (2
6
)
8
7 (2
7
)
Summary of Contents for SL-VVMES2