F893
FROM falsification
FROM
CPU
F894
EEPROM
abnormality
EEPROM Serial /
communi
- / cation
line
F8A0
Message
command is / not
appropriate
Begin sending message to AV task
(Stop the operation by error, need to
correct / firmware bug)
Firmware
bug
5.4. Self-diagnosis function for the part of loading mechanism
5.4.1. How to display
1. Turn on the power.
2. Press “SELECT” button to select DVD.
3. With no disc on the unit, hold down “STOP” button for at least 2
seconds, and then press “
” button for at least 2 seconds.
4. A loading mechanism error code is displayed if any. Refer to Table
5-1. If there are multiple error, they can be successively by
pressing “STOP” button.
5.4.2. Canceling self-diagnosis function
- Press the Standby/on button to turn off. And then press the Standby
/on button again to turn it on again.
- The contents of self-diagnosis function are stored in memory. To re-
display, perform the procedures “How to display”.
5.4.3. Clearing self-diagnosis function
- After repairing, continue to press “STOP” button for at least 5
seconds. And then “CLEAR” is displayed on the LCD about 2
seconds. / (Clearing the contents of self-diagnosis function)
- Always be sure to clear memories after completing repair.
Table 5-1
Display code
Symptom
Cause
H15
When the disc tray opens, it closes
by itself.
Disc tray open/close detect switch
(S1001) fault. / (Check and replace)
H16
When the disc tray closes, it opens
by itself.
11
Summary of Contents for SL-DT300EG
Page 35: ...30 ...
Page 36: ...31 ...
Page 37: ...32 ...
Page 38: ...33 ...
Page 39: ...34 ...
Page 40: ...35 ...
Page 53: ...C3 ECJ1VB1H102K 50V 1000P 1 48 ...
Page 65: ...21 Traverse Unit Parts Location 60 ...
Page 66: ...22 Loading Unit Parts Location 61 ...
Page 67: ...23 Schematic Diagram for printing with letter size F020300000YM KH 62 ...
Page 98: ......