39
© Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V
CHAPTER 4 TROUBLESHOOTING
Symptoms
Cause
Remedy
Control output (OSSD
1 / 2) is not turned ON.
This device is connected to the
SF4B
/
SF4B<V2>
series.
Disconnect this device.
Symptoms
Cause
Remedy
Safety output 1 / 2 is
not turned ON.
This device is connected to the
SF-C14EX
. Disconnect this device.
Error indication
Cause
Remedy
The fixed blanking function is set in all
lights received / all lights blocked condi-
tion, or the muting function is set in all
lights received condition.
#*&
lights received / all lights blocked condition,
or the muting function in all lights received
condition.
The copy function is used for the units
"&%$&$
each other (the number of sensors / the
number of beam channels / model No. is
not same).
Use the copy function for the units having
%$&
In the copy function, download the data
without uploading.
Upload the data before downloading.
The password does not match.
Input the correct password. In case you for-
get the password, contact us. (Note)
Sensor communication error 1
(Model No. is wrong)
Connect this device to
SF4B
/
SF4B<V2>
series.
Sensor communication error 2
Wrong wiring between the emitter and
receiver.
Connect the emitter and receiver correctly.
Sensor communication error 3
Effect from noise or failure of internal
circuit
Check the noise state around the
SF4B
/
SF4B<V2>
series.
Failure of EEPROM in this device.
(Failure on device)
Contact us.
Failure of EEPROM in this device.
(Failure on EEPROM data)
Contact us.
Note: The factory setting of the
SF4B
/
SF4B<V2>
series password is “0000.”
If this device does not work, press ENTER key or CANCEL key one minute after pressing ENTER
key.