9
© Panasonic Electric Works SUNX Co., Ltd. 2011 MJE-SFBHC No.0024-49V
Connecting / Setting Procedures
2-3-2 When Using in Combination with Application Expansion Unit SF-C14EX
<The 8-core cable is used>
1. Set the
SF4B
/
SF4B<V2>
series and
SF-C14EX
, and check that the
SF4B
/
SF4B<V2>
series works properly. For
mounting method of
SF4B
/
SF4B<V2>
series or
SF-C14EX
, refer to the respective
Instruction Manuals.
2. Turn OFF the power, and disconnect the ex-
tension cable with connectors connected to
the emitter side (or receiver side) of
SF4B
/
SF4B<V2>
series from
SF-C14EX
, and
then connect the emitter side (or receiver
side) of this device to the receiver side (or
emitter side) connector of
SF-C14EX
.
FUNCT
ION
㧙
CANC
EL
ENTER
㧗
Bottom cap
cable
SF4B
/
SF4B<V2>
series
(Emitter or receiver)
SF-C14EX
SF4B
/
SF4B<V2>
series
(Receiver or emitter)
This device
3. Turn ON the power, and set the function with this device.
After the power of this device is ON, a total approx. 30 sec. will be taken for data transmission with
SF4B
/
SF4B<V2>
series and
SF-C14EX
. While data transmission, “ ” lights up in revolving.
[The safety output 1 / 2 of
SF-C14EX
series are set to “OFF” while this device has been connected.]
REFERENCE
Refer to “
3-2 Functional Descriptions <When Using in Combination with Application
Expansion Unit SF-C14EX>
” for the details of the functions, and refer to “
3-3 Function
Setting (Operation Procedure)
” for the setting procedures of the functions respectively.
4. Turn OFF the power, and remove this device.
5. Connect the
SF4B
/
SF4B<V2>
series and
SF-C14EX
, and return the device to the state de-
scribed in procedure 1.
6. Check that the
SF4B
/
SF4B<V2>
series works as set at the procedure 3.
Then, inspect the
SF4B
/
SF4B<V2>
series.
REFERENCE
Refer
to
“
Chapter 4 Maintenance
” of the
SF4B / SF4B<V2>
series instruction manual for
the details of the inspection of the
SF4B / SF4B<V2>
series.
Bottom cap
cable
SF4B
/
SF4B<V2>
series
Extension cable
with connectors
SF-C14EX