background image

Exclusive Control Unit for Safety Light Curtain 

SF-C10

 

SERIES

5

ORDER GUIDE

Note:  Refer to 

SF4B

 / 

SF4B-G

 series and 

SF2B

 series for the applicable cable. 

SF-C12 spare relay set

A set of spare relays (2 safety relays and 1 removal tool) is available for the safety relay that is built into the 

SF-C12.

Model No.: 

SF-C12-RY

Designation

Appearance

Model No.

Applicable cable (Note)

Description

Connector 

connection type 

control unit

SF-C11 

Safety light curtain connection cable:

SFB-CB

(For 

SF4B

 series)

SF2B-CB

(For 

SF2B

 series)

Extension cable: 

SFB-CCJ10

Use 8-core cable with connector to connect to the safety 

light curtain.

Compatible with up to Control Category 4.

Interference prevention wires and muting function cannot 

be used.

Robust type

control unit

SF-C12 

Safety light curtain connection cable: 

SFB-CB05-MU

Extension cable: 

SFB-CCJ10

-MU

Use 12-core cable with connector to connect to the safety 

light curtain. Interference prevention wires can be used.

Compatible with up to Control Category 4.

Muting function cannot be used.

Slim type

control unit

SF-C13

Safety light curtain connection cable:

SFB-CCB

(

-MU

)

(For 

SF4B

 series)

SF2B-CCB

(For 

SF2B

 series)

Extension cable: 

SFB-CC

(

-MU

)

Use a discrete wire cable to connect to the safety light 

curtain. Muting function and interference prevention wires 

can be used.

Compatible with up to Control Category 4.

Application 

expansion 

unit for 

SF4B /

  

SF4B-G 

series

SF-C14EX

Safety light curtain connection cable:

SFB-CB

-EX

Extension cable: 

SFB-CCJ10

The muting control function and emergency stop input 

expand the applications of the safety light curtains. 

Use exclusive cable to connect to the safety light curtain.

Compatible with up to Control Category 4.

The handy-controller 

SFB-HC

 (optional) cannot be used 

with 

SF-C14EX-01

.

Handy-controller  non-compatible 

type

SF-C14EX-01

Summary of Contents for SF-C10 Series

Page 1: ... Curtain SF C10SERIES The contents of this catalog are as of October 2017 For the latest information please visit our company website The control category differs depending on the configuration and wiring of the external circuit Category 4 PLe SIL3 ...

Page 2: ...Lead wire insertion hole Ferrule sleeve terminal Please arrange separately Uses a spring method Metal enclosure with a IP65 protective structure The strong metal enclosure has a built in safety relay It has an IP65 protective structure so that it can be set up individually without needing to be inserted into a control panel Slim design 22 5 mm 0 886 in thickness so can be inserted even into narrow...

Page 3: ... units can be concentrated into a single unit which results in large space savings less wiring and less installation work High speed response 14 ms Including safety light curtain High speed response has been achieved due to the adoption of the semiconductor output Avoids the response delays that occur when using more than one safety relay unit and greatly reduces the safety light curtain safety di...

Page 4: ...ed to emergency stop input all stop When the emergency stop button is pressed this circuit switches off open the safety output and stops all equipment turntable and robot Equipped with blown lamp output for muting lamp If a lamp in one of the two muting lamps that are connected to the unit blows a warning is output It is possible to replace the lamp before both lamps blow and the equipment stops I...

Page 5: ...05 MU Extension cable SFB CCJ10 MU Use 12 core cable with connector to connect to the safety light curtain Interference prevention wires can be used Compatible with up to Control Category 4 Muting function cannot be used Slim type control unit SF C13 Safety light curtain connection cable SFB CCB MU For SF4B series SF2B CCB For SF2B series Extension cable SFB CC MU Use a discrete wire cable to conn...

Page 6: ...ctor transistor Max source current 60 mA Applied voltage same as supply voltage between the semiconductor auxiliary output and V Residual voltage 2 3 V or less at source current 60 mA Leakage current 2 mA or less Output operation Related to auxiliary output of safety light curtain On when the safety light curtain is interrupted Excess voltage category ll lll ll Indicators Power supply Ui Green LED...

Page 7: ... source current 60 mA Applied voltage same as supply voltage between the auxiliary output and V Residual voltage 2 V or less at 60 mA source current When NPN output is selected Maximum sink current 60 mA Applied voltage same as supply voltage between the auxiliary output and 0 V Residual voltage 2 V or less at 60 mA sink current Operation mode Output operation Auxiliary output 1 ON when the muting...

Page 8: ...etails SFB CB SF2B CB SFB CCJ10 24 V DC F A1 A2 0 V F G X1 X2 X3 A B NPN PNP SF C11 control circuit Receiver side connector Emitter side connector Ui FAULT INTER_LOCK RESET Safety light curtain input polarity selection switch T2 T1 AUX OUT TEST Terminal arrangement diagram Terminal Function A1 24 V DC A2 0 V 13 14 23 24 33 34 Safety output NO contact 3 41 42 Auxiliary output NC contact 1 X1 Reset ...

Page 9: ...missionhalt input Resetinput Pink Note3 Output polarity setting wire Shield Note 5 0 V Blue V Brown Cable color Gray V Brown Orange Black Synchronization Orange Synchronization KA KB Magnet contactor 24 V DC Note1 Load F G 3 M Cable color Gray with black line Notes 1 The above diagram is when using manual reset If automatic reset is used disconnect the lead from X2 and connect it to X3 In this cas...

Page 10: ...nt diagram PNP NPN A1 S11 S21 X11 S22 X12 X22 X23 AUX2 AUX1 X32 IE IE IR IR X31 AUX3 AUX4 X21 X13 S12 A2 S3 S3 S4 S4 S4 O1 O2 L2 L2 L1 34 44 64 54 L1 14 24 T2 T1 S3 Receiver side connector Emitter side connector Emergency stop switch 24 V DC 0 V SF C14EX 01 control circuit KF KD KB KE KC KA 24 V V OUT 0V V OUT 0V PLC etc Output polarity selection switch F G KA to KF Force guided relay or magnet co...

Page 11: ...ndicator AUX3 Orange Lights up when auxiliary output 3 is ON 15 Interlock 1 indicator INTER LOCK1 Yellow Lights up when interlock 1 is ON 16 Interlock 2 indicator INTER LOCK2 Yellow Lights up when interlock 2 is ON 17 Interlock 3 indicator INTER LOCK3 Yellow Lights up when interlock 3 is ON Wiring The following solid wire and twisted wires lead wire are recommended SF C11 Power supply and output l...

Page 12: ...e malfunction due to induction This product is not dust proof splash proof Be sure to put this product into a control box having IP54 construction Excluding SF C12 Avoid dust dirt and steam Take care that the product does not come in direct contact with oil grease or organic solvents such as thinner etc Note that this equipment is applicable only in the control circuit grounded in accordance with ...

Page 13: ...2 657 81 4 3 205 130 5 118 135 5 315 6 0 236 114 4 488 80 3 150 127 5 000 34 2 1 346 28 1 102 Application expansion unit SF C14EX 01 Control unit SF C13 13 5 0 531 10 0 394 4 0 157 6 5 0 256 80 3 150 80 8 3 181 Suitable for 35 mm 1 378 in width DIN rail 6 0 236 5 0 197 6 75 0 266 3 5 15 3 0 197 0 591 5 0 197 13 0 512 22 5 0 886 130 5 118 67 3 2 650 35 1 378 91 6 3 606 34 5 1 358 10 0 394 54 1 2 13...

Page 14: ...e have obtained some intellectual properties such as patent rights with respect to such applications or that the described applications may not infringe any intellectual property rights such as patent rights of a third party Printed in Japan Industrial Device Business Division 7 1 1 Morofuku Daito shi Osaka 574 0044 Japan industrial panasonic com ac e ⓒ Panasonic Industry Co Ltd Specifications are ...

Reviews: