Fig. 10
Fig. 11
14.1.5. Bias Voltage Check
1. Connect an electrical voltmeter. (Fig 12) (Fig 9 for location of test points)
2. Set the function to “TAPE” position.
3. Insert a normal blank cassette tape (QZZCRA).
4. While pressing and holding down [REC (
/
)] button, press [TAPE (
)] button to pause the recording mode. (Repeat
pressing the buttons till the recording pause mode is activated.)
5. Check that the output level is within the standard range.
Standard Range: 16 ± 3mV
Fig. 12
14.1.6. Bias Frequency Check
1. Connect a digital frequency counter (Fig 13).
2. Set the function to “TAPE” position.
3. Insert a normal blank cassette tape (QZZCRA) and press “REC” mode on main unit.
4. Check that the output frequency is within the standard range.
Standard Value: 98 ±8 kHz
Fig. 13
51
SA-AK450P / SA-AK450PC
Summary of Contents for SB-AK450
Page 8: ...8 SA AK450P SA AK450PC ...
Page 13: ...13 SA AK450P SA AK450PC ...
Page 16: ...With reference to page 13 of the operating instruction manual 16 SA AK450P SA AK450PC ...
Page 18: ...With reference to page 17 of the operating instruction manual 18 SA AK450P SA AK450PC ...
Page 29: ...10 3 Main Parts Location 29 SA AK450P SA AK450PC ...
Page 40: ...10 16 1 Replacement of Pinch Roller and Head Block 40 SA AK450P SA AK450PC ...
Page 47: ...12 4 Checking and Repairing of Power P C B 47 SA AK450P SA AK450PC ...
Page 49: ...Fig 7 49 SA AK450P SA AK450PC ...
Page 53: ...15 3 Main P C B 15 4 Panel P C B 53 SA AK450P SA AK450PC ...
Page 54: ...15 5 Power P C B Transformer P C B 15 6 XM P C B 54 SA AK450P SA AK450PC ...
Page 55: ...15 7 Waveform Chart 55 SA AK450P SA AK450PC ...
Page 64: ...SA AK450P SA AK450PC 64 ...
Page 66: ...66 SA AK450P SA AK450PC ...
Page 86: ...SA AK450P SA AK450PC 86 ...
Page 91: ...23 Exploded Views 23 1 Cabinet Parts Location SA AK450P SA AK450PC 91 ...
Page 92: ...SA AK450P SA AK450PC 92 ...
Page 93: ...23 2 Deck Mechanism Parts Locations RAA4403 S SA AK450P SA AK450PC 93 ...