11 Description of Error Code
11.1. Abnormality Detection for DECK Mechanism
No.
Error
Error Display Problem condition
1
MODE SW abnormal
H01
Normal operation during mecha transition, MODE SW abnormal is
memorized. The content of abnormality can be confirmed in the
abnormal detection mode explained in the later section.
2
REC INH SW abnormal
H02
The content of abnormality can be confirmed in the abnormal detection
mode explained in the later section.
3
HALF SW abnormal
H03
4
abnormal
F01
11.2. Abnormality detection for CD/Changer Block
No.
Error
Error Display Problem condition
1
REST SW abnormal
F15
Under normal operation (Self-Diagnostic Mode inclusive), this error
occurs when the RESTSW ON is not detected within the specified time
and shall be memorized.
2
Transmission error between CD servo
LSI and micon
F26
Under normal operation (Self-Diagnostic mode inclusive), this error occurs
when the selection is set to CD and SENSE=”H” is detected and
SENSE=”L” is not detected within a fail safe time (20ms) after system
command transmission was sent.
3
CLAMP SW abnormal
F16
Refer to CR20 control specification section 5-2 [ERROR CODE] table M-
0A error is detected.
4
BOTTOM SW abnormal
F17
Refer to CR20 control specification section 5-2 [ERROR CODE] table M-09
error is detected.
5
POSITION SW abnormal
F27
Refer to CR20 control specification section 5-2 [ERROR CODE] table M-05
~ M-08 error is detected.
6
SW1 abnormal
F28
Refer to CR20 control specification section 5-2 [ERROR CODE] table M-02
~ M-08 error is detected.
7
SW2 abnormal
F29
8
OPEN SW abnormal
H15
Refer to CR20 control specification section 5-2 [ERROR CODE] table M-01
error is detected.
11.3. Power Supply Related Error Detection
No.
Error
Error Display Problem condition
1
POWER AMP output abnormal
F61
During normal operation, if DCDET 1/2 becomes “L”, normal POWER
OFF process shall not ve executed, PCNT shall be switched to “L”
immediately. GOODBYE shall not be displayed and the error display F61
will be displayed instead.
2 seconds after the F61 display, ECONO shall be set to “L” and FL
display shall be turned off.
The error content shall be memorized when the abnormality occurs and
can be displayed in the C-mecha self-diagnostic mode described later.
36
SA-VK31EE
Summary of Contents for SA-VK31EE
Page 9: ...8 Operation Procedures 9 SA VK31EE ...
Page 42: ...14 3 1 Cassette Deck Section 14 3 2 Tuner Adjustment Point 14 3 Alignment Points 42 SA VK31EE ...
Page 74: ...A B C D E F G 1 2 3 4 5 6 7 8 9 A CD SERVO P C B REPX0437B SIDE B 74 SA VK31EE ...
Page 93: ...21 Troubleshooting Guide 93 SA VK31EE ...
Page 95: ...22 1 Deck Mechanism RAA3412 S 22 1 1 Deck Mechanism Parts Location 95 SA VK31EE ...
Page 96: ...96 SA VK31EE ...
Page 98: ...22 2 CD Loading Mechanism RD DAC026 S 22 2 1 CD Loading Mechanism Parts Location 98 SA VK31EE ...
Page 99: ...99 SA VK31EE ...
Page 101: ...22 3 Cabinet 22 3 1 Cabinet Parts Location 101 SA VK31EE ...
Page 102: ...102 SA VK31EE ...
Page 103: ...103 SA VK31EE ...
Page 115: ...22 6 Packaging 115 SA VK31EE PRT0405 D E J N S A ...