Step
Checking Item
Key operation
Device
FL Display
5
Audio Performance
(Tone ON)
Press [CLEAR] button on
remote control. To exit,
Press [
] button on main
unit or remote control
Test Box + ART20
Result OK
Result Fail
6
Audio Performance
(Tone OFF)
Press [PROGRAM] button
on remote control. To exit,
Press [
] button on main
unit or remote control
Test Box + ART20
Result OK
Result Fail
7
Test Complete - exit
Press remote [DEL]
-
-
8.3. Error Code Table
Self-Diagnosis Function provides information on any problems occuring for the unit and its respective components by displaying
error codes. Thesed error code such as U**, H** and F** are stored in memory and held unless it is cleared.
The error code is automatically display after entering into self-diagnostic mode.
Error Code Diagnosis Contents Description of error
Automatic FL Display
Remarks
F15
CD REST SW
Abnormal
CD traverse position intial
setting operation failsafe
counter (1000 ms) waiting
for REST SW to turn on.
Error No. shall be clear by
force or during cold start.
For CD unit (For Traverse).
Press [
] on main unit for next
error.
H15
CD Open SW
Abnormal
During normal operation
CD OPEN SW On fail to
be detected with 4 sec.
Error No. shall be clear by
force or during cold start.
For CD unit (For Traverse).
Press [
] on main unit for next
error.
F26
Communication
between CD servo
LSI and micro-p
abnormal.
CD function DTMS
command, after system
setting, If SENSE = ´L´
cannot be detected.
Memory shall contain F26
code. After Power on, CD
function shall continue,
error display shall be "NO
DISC". Error No. shall be
clear by force or cold start.
For CD unit (For Traverse).
Press [
] on main unit for next
error.
F61
Power Amp IC output
abnormal
During normal operation, if
DCDET
becomes
"L",
normal
POWER
OFF
process
shall
not
be
executed, PCONT shall be
switched
to
"L"
immediately. "GOODBYE"
shall not be display but the
error
display
F61
is
displayed
instead.
2
seconds
after
the
F61
displayed, ECONO shall be
set to "L" and FL display
shall be turned off. The
error
content
shall
be
memorized
when
the
abnormality occurs and can
be display in the C-mecha
self-diagnostic
mode
described later.
For Power Supply Related Error
Detection.
Press [
] on main unit for next
error.
18
SA-NS55P
Summary of Contents for SA-NS55P
Page 6: ...1 5 Caution for fuse replacement 6 SA NS55P ...
Page 13: ...7 3 Disc Information 13 SA NS55P ...
Page 21: ...9 3 Main Parts Location Diagram 21 SA NS55P ...
Page 34: ... Disassembly of gears drive 34 SA NS55P ...
Page 35: ...35 SA NS55P ...
Page 37: ...37 SA NS55P ...
Page 39: ...10 2 Checking and Repairing of Panel P C B 39 SA NS55P ...
Page 40: ...10 3 Checking and Repairing of Switch and Motor P C B 40 SA NS55P ...
Page 41: ...10 4 Checking and Repairing Transformer P C B 41 SA NS55P ...
Page 42: ...10 5 Checking and Repairing Power and AC Inlet P C B 42 SA NS55P ...
Page 43: ...10 6 Checking and Repairing Main P C B 43 SA NS55P ...
Page 44: ...10 7 Checking and Repairing CD Servo P C B 44 SA NS55P ...
Page 52: ...SA NS55P 52 ...
Page 56: ...SA NS55P 56 ...
Page 58: ...58 SA NS55P ...
Page 77: ...19 Exploded Views 19 1 Cabinet Parts Location Traverse Part Location SA NS55P 77 ...
Page 78: ...SA NS55P 78 ...
Page 79: ...19 2 Packaging SA NS55P 79 ...
Page 80: ...SA NS55P 80 ...