7.4.1. Error Code Table (For Deck Mechanism)
Error Code Diagnosis Contents Description of error
Automatic FL Display
Remarks
H01
Mode SW, plunger
and capstan motor
abnormal
Normal
operation
during
mecha
transition,
MODE
SW
abnormal
is
memorized. The content of
abnormality
can
be
confirmed in the abnormal
detection mode explained
in the later section.
For deck mechanism unit.
Press [
] on main unit for
next error.
H02
Rec INH SW
abnormal
The content of abnormality
can be confirmed in the
abnormal detection mode
explained
in
the
later
section.
For deck mechanism unit.
Press [
] on main unit for
next error.
H03
HALF SW abnormal
For deck mechanism unit.
Press [
] on main unit for
next error.
F01
Reel pulse abnormal
For deck mechanism unit.
Press [
] on main unit for
next error.
F02
TPS abnormal
For deck mechanism unit.
Press [
] on main unit for
next error.
7.4.2. Error Code Table (For CD Mechanism Unit)
Error Code
Diagnosis Contents Description of error
Automatic FL Display
Remarks
LOAD
Load operation faulty The load operation cannot
complete when time out -->
Falsaf
reverse
operates
again then time out again, it
is memorized.
For CD Mechanism unit (CR14C).
Press [EXCHANGE] on main unit for
next error.
UNLD
Unload operation
faulty
The
unload
operation
cannot complete when time
out
-->
Falsaf
reverse
operates again then time
out again, it is memorized.
For CD Mechanism unit (CR14C).
Press [EXCHANGE] on main unit for
next error.
UP
Exchange open
operation faulty
The
exchange
open
operation cannot complete
when time out --> operation
time
out
again,
it
is
memorized.
For CD Mechanism unit (CR14C).
Press [EXCHANGE] on main unit for
next error.
DOWN
Down operation faulty The down operation cannot
complete when time out -->
Falsaf
reverse
operates
again then time out again, it
is memorized.
For CD Mechanism unit (CR14C).
Press [EXCHANGE] on main unit for
next error.
OPEN
Open operation faulty The open operation cannot
complete when time out -->
Falsaf
reverse
operates
again then time out again, it
is memorized.
For CD Mechanism unit (CR14C).
Press [EXCHANGE] on main unit for
next error.
CLOSE
Close operation faulty The open operation cannot
complete when time out -->
Falsaf
reverse
operates
again then time out again, it
is memorized.
For CD Mechanism unit (CR14C).
Press [EXCHANGE] on main unit for
next error.
MODEL
Mode change to
updown operation
faulty
The
mode
change
to
updown operation cannot
complete when time out
reversing
-->
operates
again then time out again, it
is
memorized.
Mode
change to updown.
For CD Mechanism unit (CR14C).
Press [EXCHANGE] on main unit for
next error.
20
SA-AK570PL / SA-AK570GCP
Summary of Contents for SA-AK570PL
Page 7: ...7 SA AK570PL SA AK570GCP ...
Page 10: ...6 Operation Procedures 6 1 Main Unit Key Buttons Operations 10 SA AK570PL SA AK570GCP ...
Page 11: ...6 2 Remote Control Key Buttons Operations 11 SA AK570PL SA AK570GCP ...
Page 13: ...6 4 Connecting and Playing a USB Mass Storage Class Device 13 SA AK570PL SA AK570GCP ...
Page 18: ...18 SA AK570PL SA AK570GCP ...
Page 25: ...8 3 Main Components and P C B Location 25 SA AK570PL SA AK570GCP ...
Page 55: ...55 SA AK570PL SA AK570GCP ...
Page 69: ...14 1 2 Main P C B 14 1 3 SMPS P C B 69 SA AK570PL SA AK570GCP ...
Page 71: ...14 1 8 Jupiter USB P C B 71 SA AK570PL SA AK570GCP ...
Page 72: ...72 SA AK570PL SA AK570GCP ...
Page 73: ...14 2 Waveform Chart 73 SA AK570PL SA AK570GCP ...
Page 74: ...74 SA AK570PL SA AK570GCP ...
Page 76: ...SA AK570PL SA AK570GCP 76 ...
Page 86: ...86 SA AK570PL SA AK570GCP ...
Page 116: ...116 SA AK570PL SA AK570GCP ...
Page 117: ...22 Exploded Views 22 1 Cabinet Parts Location SA AK570PL SA AK570GCP 117 ...
Page 118: ...SA AK570PL SA AK570GCP 118 ...
Page 119: ...22 2 Deck Mechanism Parts Locations RAA4407 S SA AK570PL SA AK570GCP 119 ...