1. Specifications
1-2. Major Component Specifications
(A) Indoor Unit
MODEL No
.
S-26PU1U6
Source
230 - 208 VAC / 1 phase / 60Hz
Remote controller (Supplied / Optional)
Wired / Wireless (See Unit Specifications)
Controller P. C. B Ass'y
CR-26PU1U6-P
Control circuit fuse
250 VAC, 5 A
Fan (Number … diameter)
)
)
3
4
4
(
6
1
/
7
-
7
1
…
1
(
o
b
r
u
T
in. (mm)
Fan motor
Model
SFG6X - 41D6P
Source
230 - 208 V / 1 phase / 60 Hz
4
6
4
…
6
rpm
)
h
g
i
H
,
V
0
3
2
(
.
m
.
p
.
r
…
e
l
o
p
f
o
.
o
N
0
4
W
t
u
p
t
u
o
l
a
n
i
m
o
N
Coil resistance
Ω
BRW - WHT
: 170.3
,
ORG - YEL
:
43.2
(Ambient temperature 68
°
5
.
3
8
:
K
N
P
-
T
H
W
,
1
.
8
1
:
T
L
V
-
T
H
W
)
F
VLT - ORG
:
43.2
,
YEL - BLK
:
60.2
Safety device
Operating temperature
6
6
2
±
14.4
Close °F
2
.
4
7
1
±
27
VAC,
µ
F
r
o
ti
c
a
p
a
c
n
u
R
5
.
4
,
V
0
4
4
µ
F
Heat exchanger
Coil
Aluminum plate fin / Copper tube
9
.
4
1
…
2
h
c
n
i
r
e
p
s
n
i
F
…
s
w
o
R
ft.
2
(m
2
)
a
e
r
a
e
c
a
F
)
3
4
3
.
0
(
9
6
.
3
Panel
Model No.
CZ-24KPU1U
Auto louver motor
MT8 - 3C
m
p
r
3
,
W
3
,
C
A
V
0
4
2
V, W, rpm
d
e
t
a
R
…
r
o
t
o
m
r
e
v
u
o
l
o
t
u
A
Coil resistance (Ambient temperature 77
°
F)
Ω
16.430
Ω
± 8 %
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Open °F
1
SM830203-04.indb 31
15/10/16 10:44:32
Summary of Contents for : S-26PU1U6
Page 8: ...vii MEMO ...
Page 77: ...1 69 1 Specifications 1 4 Dimensional Data Outdoor Unit U 42PE1U6 U 42PS1U6 1 ...
Page 218: ...2 12 MEMO ...
Page 219: ...3 1 3 2 Indoor Units 3 2 Outdoor Units 3 14 3 ELECTRICAL DATA 3 1 3 ...
Page 220: ...3 2 3 Electrical data 3 1 Indoor Units Concealed Duct Type S 26PF2U6 S 36PF2U6 3 ...
Page 221: ...3 3 3 Electrical data 4 Way Cassette Type S 26PU1U6 S 36PU1U6 S 42PU1U6 3 ...
Page 222: ...3 4 3 Electrical data 4 Way Cassette Type S 26PU1U6 S 36PU1U6 S 42PU1U6 3 ...
Page 223: ...3 5 3 Electrical data Wall Mounted Type S 26PK1U6 3 ...
Page 224: ...3 6 3 Electrical data Wall Mounted Type S 26PK1U6 3 ...
Page 225: ...3 7 3 Electrical data Ceiling Type S 26PT1U6 S 36PT1U6 S 42PT1U6 3 ...
Page 226: ...3 8 3 Electrical data Ceiling Type S 26PT1U6 S 36PT1U6 S 42PT1U6 3 ...
Page 227: ...3 9 3 Electrical data Low Silhouette Ducted Type S 26PF1U6 S 36PF1U6 3 ...
Page 228: ...3 10 3 Electrical data Low Silhouette Ducted Type S 26PF1U6 S 36PF1U6 3 ...
Page 230: ...3 12 3 Electrical data Wall Mounted Type S 26PK2U6 3 ...
Page 232: ...3 14 3 Electrical data 3 2 Outdoor Units U 26PE1U6 3 ...
Page 233: ...3 15 3 Electrical data U 26PE1U6 3 ...
Page 234: ...3 16 3 Electrical data U 26PS1U6 3 ...
Page 235: ...3 17 3 Electrical data U 26PS1U6 3 ...
Page 236: ...3 18 3 Electrical data U 36PE1U6 3 ...
Page 237: ...3 19 3 Electrical data U 36PE1U6 3 ...
Page 238: ...3 20 3 Electrical data U 36PS1U6 3 ...
Page 239: ...3 21 3 Electrical data U 36PS1U6 3 ...
Page 240: ...3 22 3 Electrical data U 42PE1U6 3 ...
Page 241: ...3 23 3 Electrical data U 42PE1U6 3 ...
Page 242: ...3 24 3 Electrical data U 42PS1U6 3 ...
Page 243: ...3 25 3 Electrical data U 42PS1U6 3 ...
Page 244: ... MEMO 3 26 ...
Page 284: ...5 24 MEMO ...
Page 297: ...201510 ...