Troubleshooting

Symptom

Cause / Action

Indoor unit

Noise

Sound like streaming water is heard 

during operation or after operation.

• Sound of refrigerant liquid flowing inside unit

• 

Sound of drainage water through drain pipe

Cracking noise is heard during operation 

or when operation stops.

• 

Sound due to temperature changes of parts

Discharged air smells during operation.

• 

Indoor odor components, cigarette odor and cosmetic odor 

accumulated in the air conditioner and its air is discharged.

• 

The unit inside is dirty. 

(Contact your dealer.)

Dewdrops accumulate near the air outlet 

during cooling operation.

• 

Internal moisture is cooled by cool wind and accumulates as 

dewdrops.

Fog occurs during cooling operation.

• 

If the air conditioner has been installed at places such as 

restaurants where large amounts of oil mist exist, cleaning is 

necessary because the unit inside (heat exchanger) is dirty. 

(Contact your dealer.)

Fog occurs during heating operation.

• 

Defrost operation is in process.

The fan is rotating for a while even though 

operation stops.

• 

Fan rotation makes operation smooth.

• 

The fan may rotate to dry the heat exchanger depending on 

the setting.

Dust is discharged.

• 

Dust accumulated inside the indoor unit is discharged.

Outdoor unit

No operation

(When the power is turned on immediately /  

When operation is stopped and resumed 

immediately)

• Operation is not activated for the first approx. 3 minutes 

because the compressor protection circuit is activated.

Noise occurs during heating operation.

• 

Defrost operation is in process.

Steam comes out during heating operation.

The fan continues to rotate even after the 

operation is stopped using the remote 

controller.

• 

This is for smooth operation.

Check before consulting or requesting services.

OI_00_310270_Eng.indb   8

2018/12/5   13:11:24

Summary of Contents for S-180PE3R5B

Page 1: ...S 180PE3R5B S 200PE3R5B S 224PE3R5B High Static Pressure Ducted Type E3 ACXF55 23430 OUTDOOR UNIT Single Split 3 phase Refrigerant type R410A R32 Type PE2 U 180PE2R8A U 200PE2R8A U 224PE2R8A Type PZH2...

Page 2: ...in these Operating Instructions Confirm to authorized dealer or specialist on usage of specified refrigerant type Using of refrigerant other than the specified type may cause product damage burst and...

Page 3: ...s must be incorporated in the fixed wiring in accordance with the wiring rules To prevent possible hazards from insulation failure the unit must be grounded WARNING Do not use modified cord joint cord...

Page 4: ...or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to en...

Page 5: ...arm up z z Leave the power mains ON for continuous use ON NOTE Pull off the power plug from a receptacle or switch off the breaker or switch off the power disconnecting mean to isolate the air conditi...

Page 6: ...ded with the Remote Controller High spec Wired Remote Controller Optional Model No CZ RWS3 Infrared Remote Controller The receiver Model No CZ RWRC3 Air intake side duct flange rear Electrical compone...

Page 7: ...the room from rising again z z When the room temperature is more likely to reach the level that was set the fan speed is set to breeze light wind automatically Should the power failure occurs while t...

Page 8: ...rge amounts of oil mist exist cleaning is necessary because the unit inside heat exchanger is dirty Contact your dealer Fog occurs during heating operation Defrost operation is in process The fan is r...

Page 9: ...t sunlight in cooling mode Doors or windows are open Too many heat sources in the room in cooling mode Use minimum heat sources and in a short time Too many people in the room in cooling mode Lower th...

Page 10: ...5 0 BTU h 68 200 76 400 85 300 Sound pressure level High dB A 46 46 47 Medium dB A 44 44 45 Low dB A 41 41 42 Sound power level High dB A 78 78 79 Medium dB A 76 76 77 Low dB A 73 73 74 Unit dimension...

Page 11: ...11 MEMO OI_00_310270_Eng indb 11 2018 12 5 13 11 24...

Page 12: ...Printed in Malaysia Panasonic Corporation 2018 ACXF55 23430 DC1218 0 Panasonic Corporation http www panasonic com OI_00_310270_Eng indb 12 2018 12 5 13 11 24...

Reviews: