If the refrigerant comes in contact

with a flame, it produces a toxic

gas.
For safety, be sure to turn the 

air conditioner off and also to 

disconnect the power before 

cleaning or servicing.
Pull off the power plug from 

a receptacle, or switch off  

the breaker, or switch off 

the power disconnecting mean to 

isolate the air conditioner from the 

main power supply in case of 

emergency.
Dispose of according to national 

and/or local legislation.

This product must not be modified 

or disassembled under any 

circumstances.

Modified or disassembled unit 

may cause fire, electric shock or 

injury.
Do not clean inside the indoor and 

outdoor units by users. Engage 

authorized dealer or specialist for 

cleaning.
In case of malfunction of this 

appliance, do not repair by yourself. 

Contact the sales dealer or service 

dealer for a repair and disposal.

Provide a power outlet to be used 

exclusively for each unit, and a

power supply disconnect, Earth 

Leakage Circuit Breaker (ELCB)

or Residual Current Device (RCD) 

for overcurrent protection should

be provided in the exclusive line.
Provide a power outlet 

exclusively for each unit, and full 

disconnection means having a 

contact separation in all poles 

must be incorporated in the fixed 

wiring in accordance with the 

wiring rules.
To prevent possible hazards 

from insulation failure, the 

unit must be grounded.

WARNING

Do not use modified 

cord, joint cord, 

extension cord or 

unspecified cord to prevent 

overheating and fire. 

The appliance shall be stored 

in a room without continuously 

operating ignition sources (for 

example: open flames, an 

operating gas appliance or an 

operating electric heater).
Be aware that refrigerants may 

not contain an odour.
An unventilated area where 

the appliance using flammable 

refrigerants is installed shall be 

so constructed that should any 

refrigerant leak, it will not stagnate 

so as to create a fire or explosion 

hazard. 
The appliance shall be stored 

in a well-ventilated area where 

the room size corresponds to 

the room area as specified for 

operation.
After the unit is installed, never 

fail to ask the installer for the floor 

space of the room where the unit 

is installed and the refrigerant 

charge amount.
In case the unit or the room 

divider is changed, never fail to 

consult the sales dealer or service 

dealer.
Do not use means to accelerate 

the defrosting process or to clean, 

other than those recommended 

by the manufacturer.
Do not pierce or burn.
In cases that require mechanical 

ventilation, ventilation openings 

shall be kept clear of obstruction.

OI_00_310270_Eng.indb   3

2018/12/5   13:11:22

Summary of Contents for S-180PE3R5B

Page 1: ...S 180PE3R5B S 200PE3R5B S 224PE3R5B High Static Pressure Ducted Type E3 ACXF55 23430 OUTDOOR UNIT Single Split 3 phase Refrigerant type R410A R32 Type PE2 U 180PE2R8A U 200PE2R8A U 224PE2R8A Type PZH2...

Page 2: ...in these Operating Instructions Confirm to authorized dealer or specialist on usage of specified refrigerant type Using of refrigerant other than the specified type may cause product damage burst and...

Page 3: ...s must be incorporated in the fixed wiring in accordance with the wiring rules To prevent possible hazards from insulation failure the unit must be grounded WARNING Do not use modified cord joint cord...

Page 4: ...or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to en...

Page 5: ...arm up z z Leave the power mains ON for continuous use ON NOTE Pull off the power plug from a receptacle or switch off the breaker or switch off the power disconnecting mean to isolate the air conditi...

Page 6: ...ded with the Remote Controller High spec Wired Remote Controller Optional Model No CZ RWS3 Infrared Remote Controller The receiver Model No CZ RWRC3 Air intake side duct flange rear Electrical compone...

Page 7: ...the room from rising again z z When the room temperature is more likely to reach the level that was set the fan speed is set to breeze light wind automatically Should the power failure occurs while t...

Page 8: ...rge amounts of oil mist exist cleaning is necessary because the unit inside heat exchanger is dirty Contact your dealer Fog occurs during heating operation Defrost operation is in process The fan is r...

Page 9: ...t sunlight in cooling mode Doors or windows are open Too many heat sources in the room in cooling mode Use minimum heat sources and in a short time Too many people in the room in cooling mode Lower th...

Page 10: ...5 0 BTU h 68 200 76 400 85 300 Sound pressure level High dB A 46 46 47 Medium dB A 44 44 45 Low dB A 41 41 42 Sound power level High dB A 78 78 79 Medium dB A 76 76 77 Low dB A 73 73 74 Unit dimension...

Page 11: ...11 MEMO OI_00_310270_Eng indb 11 2018 12 5 13 11 24...

Page 12: ...Printed in Malaysia Panasonic Corporation 2018 ACXF55 23430 DC1218 0 Panasonic Corporation http www panasonic com OI_00_310270_Eng indb 12 2018 12 5 13 11 24...

Reviews: