Rx450AC Rx550DC MK3 Installation Manual - V19 30Sep05.doc
Page 5/28
3. Rx450 Technical Specification
Power Requirements
230Vac or (110Vac or 24Vac as factory fitted option)
Max Load
5A @ 230V
(1150 W)
Receiver Current Draw
24VA max
Fuses
Auxiliary fuse
F2
5A T
(20mm ceramic cartridge)
Outputs
8 single pole relays (snubbed)
1. Left Motor
5. Autopan (Interlocked with Pan)
2. Right Motor
6. Lights (1000W max)
3. Up Motor
7. Wash
4. Down Motor
8. Wipe
Facilities
LED readout for continual system status.
Programming menu with On Screen Display.
Gain
REMOTELY ADJUSTABLE
Video launch amplifier provided with cable length adjustment
12Vdc/500mA
camera
power
provided.
Colour coded outlets – live, neutral, earth and low voltage.
Telemetry Signal
2 or 4 wire Panasonic RS485
Auto Iris Output
Returns to original setting 15 seconds after key release. Level
programmable from controller.
Video Input
1v p-p 75
Ω
terminated input via BNC socket.
Video Output
1v to 4v p-p 75
Ω
impedance via BNC socket.
Lens Drive
REMOTELY ADJUSTABLE
Adjustable via menu between 6 – 12Vdc. Inching speed selectable via
menu between 0 – 12Vdc. 1 second inching built in. Provides drive for
Zoom & Focus. Each lens drive carries red and green LEDs to indicate
direction and drive voltage.
Presets
Inputs are provided for pan, tilt, zoom & focus preset feedback pots.
These are 10 bit resolution. Up to 64 full-scene presets can be stored
within the receiver, i.e. pan, tilt, zoom, focus.
Other Outputs
RS485 Serial port available to drive advance features on selected
cameras.
Additional Information
Autopan auxiliary output or software Random Pan
Sequential preset patrol. The preset dwell is programmable individually.
Datum - return to preset 1, start preset patrol or random pan after menu
programmable duration of inactivity.
Iris output - either direct drive for 3 motor lens or Autoiris override voltage
for Seiko/Cosmicar lenses etc.
8 alarm inputs, volts free normally closed contacts. A single opening volts
free contact sums the alarms either immediately or as the preset is
approached. If a video transmission system is activated with the alarm
output, then setting the alarm to delayed prevents unwanted frames being
transmitted.
Options
24Vac/230Vac output is link selectable with link J3
Boxed Dimensions
Width: 380mm, Length: 190mm, Height: 130mm
Weight
3.43kg