Rx450AC Rx550DC MK3 Installation Manual - V19 30Sep05.doc
Page 12/28
Example connection diagrams.
Single Rx550 with WJ-FS616
Flexible Conduit
Coax - From Camera
Multicore - Pan/Tilt/
Aux
16 x 0.2mm
Screened multicore
Lens drive & preset
inputs
Termination fitted
Address 01
WJ-FS616 Multiplexer
230Vac
Supply
Spur to
provide
isolation
Coax - To WJ-FS616
RS485 telemetry
cable
Pan/Tilt
Mechanism
Housing &
Camera
Multicore - Pan/Tilt/
Aux
16 x 0.2mm
Camera 1 I/
P
RS485 Telemetry
Connection details
T
B
Rx550
T
A
R
B
R
A
Rx550
T
B
T
A
R
B
R
A
4 WIRE
2 WIRE
FS616
T
R
A
T
R
B
G
N
D
R
A
R
B
screen
screen
T
R
A
T
R
B
G
N
D
R
A
R
B