![Panasonic Quasar PVQ-1310 Service Manual Download Page 6](http://html1.mh-extra.com/html/panasonic/quasar-pvq-1310/quasar-pvq-1310_service-manual_4119188006.webp)
is applied, find the cause. Check R503, R5505, C5507, C513 and
D503.
3. Carefully check above specified parts and related circuits and
parts. When the circuit is repaired, try the horizontal oscillator
disable circuit test again.
CIRCUIT EXPLANATION
HORIZONTAL OSCILLATOR DISABLE CIRCUIT
The positive DC voltage, supplied from the D503 cathode for monitoring high voltage, is applied
to the IC5301 Pin11 through R503 and R5504. Under normal conditions, the voltage at IC5301 Pin
11 is less than approx 3 V. If the high voltage at Flyback Tr Pin 5 exceeds the specified voltage,
the positive DC voltage which is supplied from the D503 cathode also increases. The increased
voltage is applied to IC5301 Pin11 through R503 and R5504. Due to the increased voltage at
IC5301 Pin11, the horizontal oscillator frequency increases, the picture goes out of horizontal
sync, the beam current decreases and the picture becomes dark in order to keep X-radiation
under specification.
Figure 3
3. PREVENTION OF ELECTROSTATIC DISCHARGE
(ESD) TO ELECTROSTATICALLY SENSITIVE (ES)
DEVICES
Some semiconductor (solid state) devices can be damaged easily by static electricity. Such
components commonly are called Electrostatically Sensitive (ES) Devices. Examples of typical
ES devices are integrated circuits and some field-effect transistors are semiconductor "chip"
components. The following techniques should be used to help reduce the incidence of
component damage caused by electrostatic discharge (ESD).
1. Immediately before handling any semiconductor component or
semiconductor-equipped assembly, drain off any ESD on your
body touching a known earth ground. Alternatively, obtain and
wear a commercially available discharging ESD wrist strap, which
should be removed for potential shock reasons prior to applying
power to the unit under test.
2. After removing an electrical assembly equipped with ES devices,
place the assembly on a conductive surface such as aluminum
foil, to prevent electrostatic charge buildup or exposure of the
assembly.
6
Summary of Contents for Quasar PVQ-1310
Page 25: ...Fig D5 25 ...
Page 29: ...6 2 2 Inner Parts Location Fig J1 1 29 ...
Page 30: ...6 2 3 EJECT Position Confirmation Fig J1 2 30 ...
Page 31: ...6 2 4 Grounding Plate Unit Full Erase Head and Cylinder Unit Fig J2 1 31 ...
Page 44: ...6 3 CASSETTE UP ASS Y SECTION 6 3 1 Top Plate Wiper Arm Unit and Holder Unit Fig K1 1 44 ...
Page 82: ...82 ...
Page 86: ...11 2 MECHANISM BOTTOM SECTION 86 ...
Page 87: ...11 3 CASSETTE UP COMPARTMENT SECTION 87 ...
Page 88: ...11 4 CHASSIS FRAME SECTION 1 A B C D E F G 88 ...
Page 89: ...11 5 CHASSIS FRAME SECTION 1 H I J K L 89 ...
Page 90: ...11 6 CHASSIS FRAME SECTION 2 90 ...
Page 91: ...11 7 PACKING PARTS AND ACCESSORIES SECTION A B C D E F G 91 ...
Page 92: ...11 8 PACKING PARTS AND ACCESSORIES SECTION H I J K L 92 ...
Page 113: ...R4021 ERJ6GEYJ473V MGF CHIP 1 10W 47K 113 ...
Page 115: ...R5515 ERDS2TJ332 3 3K 115 ...
Page 135: ...R885 ERDS2TJ104 100K 135 ...