3. If the reading is out of specification, make sure that there is no
dust or foreign material between the Brake Pad of Tension Control
Arm Unit and the S Reel Table.
After cleaning, the reading of tension measurement is still out of
specification, replace the Tension Arm Unit and the Tension
Control Arm Unit.
Fig. M2-2
Note:
A. Be sure that the three probes of the meter are all in solid
contact with the tape, but not touching any other parts of the
mechanism.
B. It is recommended that measurements should be repeated at
least three (3) times because the tension meter is very sensitive
to external vibrations.
7.2.2.2. MR HEAD GAP ADJUSTMENT
Purpose:
To properly pick up the FG Signal.
Symptom of Misadjustment:
49
Summary of Contents for Quasar PVQ-1310
Page 25: ...Fig D5 25 ...
Page 29: ...6 2 2 Inner Parts Location Fig J1 1 29 ...
Page 30: ...6 2 3 EJECT Position Confirmation Fig J1 2 30 ...
Page 31: ...6 2 4 Grounding Plate Unit Full Erase Head and Cylinder Unit Fig J2 1 31 ...
Page 44: ...6 3 CASSETTE UP ASS Y SECTION 6 3 1 Top Plate Wiper Arm Unit and Holder Unit Fig K1 1 44 ...
Page 82: ...82 ...
Page 86: ...11 2 MECHANISM BOTTOM SECTION 86 ...
Page 87: ...11 3 CASSETTE UP COMPARTMENT SECTION 87 ...
Page 88: ...11 4 CHASSIS FRAME SECTION 1 A B C D E F G 88 ...
Page 89: ...11 5 CHASSIS FRAME SECTION 1 H I J K L 89 ...
Page 90: ...11 6 CHASSIS FRAME SECTION 2 90 ...
Page 91: ...11 7 PACKING PARTS AND ACCESSORIES SECTION A B C D E F G 91 ...
Page 92: ...11 8 PACKING PARTS AND ACCESSORIES SECTION H I J K L 92 ...
Page 113: ...R4021 ERJ6GEYJ473V MGF CHIP 1 10W 47K 113 ...
Page 115: ...R5515 ERDS2TJ332 3 3K 115 ...
Page 135: ...R885 ERDS2TJ104 100K 135 ...