5.1.9. METHOD FOR LOADING/UNLOADING OF MECHANISM
5.1.9.1. (Manual Method)
Turn the Loading Gear clockwise (for loading) or counterclockwise (for unloading) using needlenose
pliers etc.
Note:
Do not use this method if Mechanism is jammed or locked.
Fig. 7-1
5.1.9.2. (Electrical Method)
Apply +10.0 V DC Power Supply to the Loading Motor terminals.
Loading
DC + to Portion "a," DC - to Portion "b"
Unloading
DC - to Portion "a," DC + to Portion "b"
CAUTION:
Before applying DC Power Supply, be sure to cut the Motor Leads with a
cutter, etc.
Otherwise, the Loading Motor Drive IC (IC2501) may be damaged.
When reconnecting the Motor Leads, solder at below / 320 °C for less
than 3 seconds.
Fig. 7-2