– 46 –
Chapter 3 Preparation — Inspections before shooting
5
Press the <SETUP> button to display the [SET01:TC/UB] screen of SmartUI.
6
Set the [TC_MD] to [R-RUN].
7
Press the <HOME> button to display the [HOME] screen of SmartUI.
8
Press the <REC> button.
Ensure that the number in the counter display changes when the recording starts.
9
Press the <REC> button again.
Ensure that the number in the counter display stops changing when the recording stops.
10
Press the <SETUP> button to display the [SET01:TC/UB] screen of SmartUI.
11
Set the [TC_MD] to [F-RUN].
12
Press the <HOME> button to display the [HOME] screen of SmartUI.
Ensure that the number in the counter display changes regardless of the recording status.
13
Push the <DISP/MODE CHK> switch towards the <CHK> side and check the date and time displayed on the viewfinder.
If [DATE], [TIME], and the time zone is incorrect, set the correct date/time. (page 43)
@
@
NOTE
t
Note that date and time data based on [DATE], [TIME], and the time zone settings is recorded in the clip and affects the playback order in the
thumbnail operations. Be careful.