List  of  compatible  signals

The  signals  that  can  be  input  to  this  projector  are  shown  in  the  table  below.  Horizontal  scanning  fre-
quencies  of  25  kHz  to  80 kHz (15  kHz  to  100  kHz  for  RGB  signals),  vertical  scanning  frequencies  of 
50 Hz  to  120 Hz (50  Hz  to  100  Hz  for  RGB  signals),  and  a  dot  clock  of  162 MHz  maximum (140  MHz
maximum  for  RGB  signals) can  be  input.

NOTE:

The  native  resolution  of  this  projector  is  1,024  ×  768 pixels.  If  the  display  resolution  of  the  input  signal  is  different  from  the
native  resolution,  image  compression  or  expansion  will  be  used  to  convert  the  input  signal  to  a  level  within  the  native  resolution.

Display mode

Display
resolution
(dots)*

1

Scanning frequency

H
(kHz)

V
(kHz)

Dot clock
frequency
(MHz)

Format

720 × 480i

720 × 576i

640 × 480i

768 × 576i

640 × 480

768 × 576

1280 × 720

1920 × 1035i

1920 × 1080i

640 × 400

640 × 480

720 × 400

640 × 480

800 × 600

832 × 624

1024 × 768

1024 × 768i

1024 × 768

15.7

15.6

15.7

15.6

31.5

31.3

45.0

37.5

33.8

33.8

28.1

31.5

31.5

37.5

37.9

37.9

43.3

31.5

35.0

35.0

32.7

34.5

35.2

37.9

37.9

38.0

38.6

46.9

48.1

53.7

49.7

44.0

46.9

47.0

48.4

48.5

58.0

60.0

60.3

61.0

62.0

63.5

56.5

68.7

36.0

35.5

60.2

59.9

50.0

59.9

50.0

59.9

50.0

60.0

50.0

60.0

60.0

50.0

70.1

59.9

75.0

72.8

74.4

85.0

70.1

66.6

66.7

51.1

55.4

56.3

60.3

61.0

60.5

60.3

75.0

72.2

85.1

74.6

54.6

58.2

58.3

60.0

60.0

72.0

75.0

74.9

75.7

77.1

79.4

70.1

85.0

87.2

87.0

75.1

12.3

14.8

25.2

29.5

74.3

74.3

74.3

74.3

74.3

25.2

25.2

31.5

31.5

31.5

36.0

28.3

31.3

30.2

32.7

36.4

36.0

40.0

40.0

40.1

38.6

49.5

50.0

56.3

57.3

59.1

63.0

61.7

65.0

65.2

74.7

78.8

79.3

81.0

84.3

83.4

75.0

94.5

47.3

44.9

80.0

NTSC/NTSC4.43/PAL-M/PAL60

PAL/PAL-N/SECAM

480i (525i)

576i (625i)

480p (525p)

576p (625p)

720p

1035i

1080i

VGA

MAC LC13

MAC13

SVGA

MAC16

XGA

MAC19

VIDEO/S-VIDEO

YP

B

P

R

/RGB

HDMI/YP

B

P

R

/RGB

RGB

HDMI/RGB

RGB

HDMI/RGB

RGB

HDMI/RGB

RGB

HDMI/RGB

RGB

*1 The  “i”  appearing  after  the  resolution  indicates  an  interlaced  signal.

Summary of Contents for PT-VW440

Page 1: ...S P E C F I L E Product Number PT VX500 Product Name LCD Projector As of June 2012 Specifications and appearance are subject to change without notice SFL12M010 1 1 1 2 ...

Page 2: ...162 MHz or lower fH 15 kHz 100 kHz fV 50 Hz 100 Hz dot clock 140 MHz or lower Signals above 140 MHz are downsampled 480i 525i fH 15 75 kHz fV 60 Hz 576i 625i fH 15 63 kHz fV 50 Hz 480p 525p fH 31 50 kHz fV 60 Hz 576p 625p fH 31 25 kHz fV 50 Hz 720 750 60p fH 45 00 kHz fV 60 Hz 720 750 50p fH 37 50 kHz fV 50 Hz 1080 1125 60i fH 33 75 kHz fV 60 Hz 1080 1125 50i fH 28 13 kHz fV 50 Hz fH 15 75 kHz fV ...

Page 3: ... 3 V DC R03 LR03 AAA type battery 2 Approximately 7 m 23 ft when operated from directly in front of the signal receptor 52 110 18 mm 2 1 16 4 11 32 23 32 inches Approx 67 g 2 4 oz including batteries Power cord 1 2 for PT VX500EA AC power cord holder 1 Wireless remote control unit 1 Batteries for remote control R03 LR03 AAA type 2 Carrying bag 1 Computer cable 1 8 m 5 ft 11 in for VGA 1 Software C...

Page 4: ...le S P E C F I L E PT VX500 LCD Projector As of June 2012 SFL12M010 1 4 1 2 Terminals 1 5 6 7 8 9 10 11 2 3 4 1 Computer 1 input 2 Computer 2 input computer 1 output 3 HDMI input 4 LAN connector 5 Serial input 6 Video input 7 Audio input for video S Video 8 Audio input for computer 1 9 Audio input for computer 2 mic input 10 Audio output 11 S Video input ...

Page 5: ...t and the ceiling 0 76 m 1 02 m 1 27 m 1 52 m 1 78 m 2 03 m 2 29 m 2 54 m 3 05 m 3 81 m 5 08 m 6 35 m 7 62 m 0 7 0 9 1 2 1 4 1 7 1 9 2 2 2 4 2 9 3 6 4 8 6 0 7 2 1 1 1 5 1 9 2 3 2 7 3 1 3 5 3 9 4 7 5 8 7 8 9 7 11 7 0 05 0 06 0 08 0 09 0 11 0 12 0 14 0 15 0 18 0 23 0 31 0 38 0 46 0 23 0 31 0 38 0 46 0 53 0 61 0 69 0 76 0 91 1 14 1 52 1 91 2 29 30 40 50 60 70 80 90 100 120 150 200 250 300 2 3 3 0 3 9...

Page 6: ... include a slight error 3 0 3 0 1 5 1 5 Installable angle Install the projector at an angle within the range shown below Vertical direction The projector may be installed at a vertical angle of 30 Horizontal direction The projector may be installed at a horizontal angle of 15 H Width of projected image V Height of projected image 0 4V Standard postition of projected image Shift range Optical axis ...

Page 7: ...640 400 640 480 720 400 640 480 800 600 832 624 1024 768 1024 768i 1024 768 15 7 15 6 15 7 15 6 31 5 31 3 45 0 37 5 33 8 33 8 28 1 31 5 31 5 37 5 37 9 37 9 43 3 31 5 35 0 35 0 32 7 34 5 35 2 37 9 37 9 38 0 38 6 46 9 48 1 53 7 49 7 44 0 46 9 47 0 48 4 48 5 58 0 60 0 60 3 61 0 62 0 63 5 56 5 68 7 36 0 35 5 60 2 59 9 50 0 59 9 50 0 59 9 50 0 60 0 50 0 60 0 60 0 50 0 70 1 59 9 75 0 72 8 74 4 85 0 70 1...

Page 8: ...0 81 3 87 5 93 8 65 3 74 0 74 6 59 9 74 9 84 8 50 0 60 1 59 8 70 0 72 0 70 0 72 0 74 9 60 0 84 8 60 0 72 0 60 0 60 0 75 1 65 2 75 6 66 0 60 0 58 6 60 0 60 0 60 0 67 2 76 1 60 2 75 0 60 0 72 0 60 2 85 0 86 0 94 0 86 7 75 1 75 1 60 2 60 1 59 9 59 9 60 0 60 0 65 0 70 0 75 0 60 0 59 9 59 9 79 5 102 3 117 5 68 6 79 4 83 5 95 0 97 8 98 9 102 8 106 5 108 0 122 5 86 7 86 7 100 1 86 7 100 0 92 0 105 1 94 5...

Page 9: ...t for 60 sec onds then try sending or receiving again When sending multiple commands be sure to wait for at least 0 5 second after receiving a response from the projector before sending the next command Additional time is sometimes required for response due to processing inside the projector Set the time out period for command response to 10 seconds or more Start 1 byte End 1 byte Colon 1 byte Par...

Page 10: ...nema Picture mode Real Picture mode Blackboard Picture mode Colorboard Picture mode Image 1 Picture mode Image 2 Picture mode Image 3 Picture mode Image 4 Volume up Volume down AV mute Digital zoom Enlargement Digital zoom Reduction PON POF AVL pl IIS input signal OFZ off on VPM STD VPM DYN VPM CIN VPM REA VPM BBD VPM CBD VPM IM1 VPM IM2 VPM IM3 VPM IM4 AUU AUD OSH DZU DZD 0 0 63 1 Command Paramet...

Page 11: ...xample To set the volume to 30 send the command as shown below STX AVL 30 ETX Start Command Parameter End NOTE When sending commands without parameters a colon is not necessary NOTE If a wrong command is received the projector will send an ER401 command to the computer Parameter format Parameter format Size Byte Definition pl off on input signal power condition lamp condition acctch 3 1 or 2 bytes...

Page 12: ...stall it in an enclosed space add a separate ventilation system If ventilation is insufficient hot air will accumulate at the intake opening This may cause the projector s protective circuit to interrupt projector operation 500 mm 1 ft 8 in or more 500 mm 1 ft 8 in or more 1 000 mm 3 ft 3 in or more Operating the projector continuously 1 If the projector is to be operated continuously 12 hours or ...