-50-
Electrical Adjustments
Group/
Item
Item Name
Function
Initial
Range
Note
5 DIMMER_CTRL_
LEVEL6
Level-6 data for dimming
brightness: when less than the
dimming level 6
42
0 - 255
6 DIMMER_CTRL_
LEVEL7
Level-7 data for dimming
brightness: when less than the
dimming level 7
49
0 - 255
7 DIMMER_CTRL_
LEVEL8
Level-8 data for dimming
brightness: when less than the
dimming level 8
56
0 - 255
8 DIMMER_CTRL_
LEVEL9
Level-9 data for dimming
brightness: when less than the
dimming level 9
63
0 - 255
9 DIMMER_CTRL_
LEVEL10
Level-10 data for dimming
brightness: when less than the
dimming level 10
70
0 - 255
DIMMER_CTRL_
LEVEL11
Level-11 data for dimming
brightness: when less than the
dimming level 11
77
0 - 255
11 DIMMER_CTRL_
LEVEL12
Level-12 data for dimming
brightness: when less than the
dimming level 12
84
0 - 255
12 DIMMER_CTRL_
LEVEL13
Level-13 data for dimming
brightness: when less than the
dimming level 13
91
0 - 255
13 DIMMER_CTRL_
LEVEL14
Level-14 data for dimming
brightness: when less than the
dimming level 14
98
0 - 255
14 DIMMER_CTRL_
LEVEL15
Level-15 data for dimming
brightness: when less than the
dimming level 15
105
0 - 255
15 DIMMER_AVERAGE_
POINT
Luminance Data Avarage Point
for Mimmer
4
1 - 16
16 DIMMER_AVERAGE_
DATA
Luminance Data Avarage Value
for Dimmer
-
-
* Read only
17 DIMMER_LEVEL_AUTO Current Dimmer Leverl
-
-
* Read only
18 DIMMER_LEVEL_
NORMAL
Normal Dimmer Level
15
0 - 15
19 DIMMER_LEVEL_ECO
Eco Dimmer Level
0
0 - 15
20 Panel life mode
Panel life mode
0
0 - 1
21 VOLTAGE_LEVEL
Lamp Voltage
-
-
Unit: 8bit(Raw Data) * Read only
22 DIMMER_LEVEL_HIGH
15
0 - 15
Group
230
VBI Slice Level
0 Generic Initial Slicing
Level
PW190 register 0xE344
9
0-255
1 Generic High Level
Threshold
PW190 register 0xE345
0
0-255
2 Generic Low Level
Threshold
PW190 register 0xE346
0
0-255
3 Generic Minimum Low
Level
PW190 register 0xE347
0
0-255
4 Generic Maximum High
Level
PW190 register 0xE348
255
0-255
Group
250
FAN Control * Fan volltage adjustment
0 FAN1 MIN ADJUST
(DAC)
DAC Output for Fan
Adjust the tolerance of DAC
and Fan Volage.
* Lamp mode is forced Eco
28
0-255
1 FAN1 MAX ADJUST
(DAC)
205
0-255
2 FAN2 MIN ADJUST
(DAC)
36
0-255
3 FAN2 MAX ADJUST
(DAC)
207
0-255
4 FAN3 MIN ADJUST
(DAC)
30
0-255
5 FAN4 MAX ADJUST
(DAC)
235
0-255
Group
252
Fan Option
0 HI-LAND SWITCH
0: Normal, 1: Hi-Land , 2-4:
Hi-Land "1-3"
0
0 - 2
* Read only
1 SAFETY Switch
For test purpose
0
0.3 - 6
2 FAN MANUAL SWITCH
0: Auto, 1: Manual
0
0 - 3
3 FAN1 MANUAL VOLT-
AGE
Fan Voltage (unit : 0.1V)
Effective only when Fan
Manual switch is 1
100
0 - 255
4 FAN2 MANUAL VOLT-
AGE
100
0 - 255
5 FAN3 MANUAL VOLT-
AGE
100
0 - 255